Installation guide
26 en | Installation with Wiegand and Access Easy Controller (AEC) Access Control by Example
| 1.0 | 2009.10 Introductory Guide Bosch Security Systems
4.5.3 Configuring the AEC software
Step
no.
Where Step description Illustrations / Reference
1AEC and
Computer
Use a normal network cable to connect the AEC’s
ethernet port to an ethernet port in the network hub.
AEC2.1 Hardware Manual and
AEC2.1 Software Manual
2 Computer Open a Web browser application (Internet Explorer 7.0
and later) and enter the controller's default IP address
192.168.0.41.
If you have changed the IP address enter the new IP
address.
AEC2.1 Hardware Manual and
AEC2.1 Software Manual.
3 Computer From the main page select Configuration > Device >
Door. Edit the description of the existing door
configuration as Main_Entrance, Lab, Storeroom and
Office.
AEC2.1 Software Manual
4 Computer For the Main entrance define a Schedule for public
visiting hours between 9:00 and 16:00.
AEC2.1 Software Interface:
Configuration > Schedules
5 Computer Assign the above defined schedule to the Main
Entrance and set the schedule to unlock the door.
AEC2.1 Software Interface -
Configurator: Configuration >
Device > Door > Scheduling Options
6 Computer Assign Access groups to the individual doors, e.g:
– All_Staff (for Main entrance and Storeroom)
– Doctor (for Office and Laboratory)
– Receptionist (for Office)
– Technician (for Laboratory)
AEC2.1 Software Interface -
Configurator: Card > Access Groups
7 Computer Create the users e.g. Doctor, Receptionist, Lab
Technician and assign individual card numbers to
access the doors.
Assign the appropriate access groups to each user, i.e:
– Receptionist: All_Staff and Receptionist.
– Technician: All_Staff and Technician.
– Doctor: All Staff and Doctor
AEC2.1 Software Interface -
Configurator: Card > Card
Administration