Specifications
PARAMETER REFERENCE MANUAL127
CONFIG MENU PARAMETERS
¦ Page A
Value Meaning
SysEx Page A parameters are transmitted/received as system exclusive packets.
Controller data reception is disabled.
Controller Data Page A parameters are transmitted/received in the form of MIDI CC (see glossary)
data.
¦ Page B
Value Meaning
SysEx Page B parameters are transmitted and received in the form of system exclusive
packets. Controller data reception is disabled.
Poly Pressure Page B parameters are transmitted and received in the form of Poly-pressure data.
Inputs
¦ Boost
0 to 127: Boosts the input - use this only for very low level signals.
¦ Input Thru
0 to 127: The level of external signal sent directly to output1.
¦ Sensitivity
+16 dBV .. -16 dBV: Select sensitivity to suit different external audio sources.
Value Meaning
To Edit Buffer Incoming bank data is not stored, but is treated as a series of individual programs. These
will appear sequentially in the edit buffer – useful for trying out sounds without having to
overwrite an entire bank.
Verify Incoming bank data is compared with the memory in the Virus, after which a status
message appears. Use this setting to check whether a bulk dump has been successful.
MIDI Dump TX
¦ Transmit MIDI Dump
Transmits various types of system exclusive data to an external device e.g. a computer or another Virus.
Value Meaning
Single Buffer The contents of the single Edit buffer i.e. the current Single program (or Part without the
Multi settings). This function is also available in the STORE menu for easy access.
Single Bank A All 128 programs in Bank A.
Single Bank B All 128 programs in Bank B.
Single Bank C All 128 programs in Bank C.
Single Bank D All 128 programs in Bank D.
Controller Dump A Single program, but in the form of a succession of individual parameter changes.
These can take the form of MIDI CCs, Polypressure or Sysex, depending on the value of
two other parameters. The Controller Dump setting is mainly used for updating the data
in parameter-based editors (e.g. a Logic environment) and can be relatively slow.
Arrangement All 16 sounds in the current Multi buffer or Sequencer mode buffer plus the additional
“multi” settings.
Multi Bank All Multi programs.
MIDI Control: Governs how Page A and Page B parameters are handled during MIDI communication with
e.g. a computer or MIDI controller unit. Note that system exclusive data is always recognized, irrespective of
the settings here.