Intraoral Digital Video Camera System Part Number A5000 Operator’s Manual
TABLE OF CONTENTS Page Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Air Techniques Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 On-Line Warranty Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CONGRATULATIONS Congratulations on your purchase of the Acclaim Intraoral Digital Video Camera System, the latest camera in the dental video imaging product line from Air Techniques, a leading manufacturer of dental equipment since 1962. The Acclaim Camera System design offers the benefits of a flexible and reliable image capturing system that is easily integrated into any practice.
SAFETY NOTICE GENERAL This equipment has been designed to minimize exposure of personnel to hazards. While the Acclaim Camera System is designed for safe operation, certain precautions must be observed. Use of the Acclaim Camera System not in conformance with the instructions specified in this manual may result in permanent failure of the unit.
BOX CONTENTS Each component of the Acclaim Camera System is shipped packaged in individual protective containers all packed in a single box, which includes: Item Supplied Part No.
KEY PARTS IDENTIFICATION CAMERA HANDPIECE P/N A5020 POWER SUPPLY ADAPTER USB 2.
COMPONENT DESCRIPTION Camera Handpiece Holder with Double-Sided Adhesive Fastener - The Camera Handpiece Holder, part number A5145, can be fastened in a convenient location for safe storage of the Camera Handpiece when it is not in use. In addition to storage, the Camera Handpiece Holder also has built-in magnets that turn off the Camera Handpiece power. This feature conserves energy and equipment wear so the camera is ready and operational when needed.
HANDPIECE KEYPAD BUTTON FUNCTIONS Acclaim Camera Handpiece A5020 2 1 3 Keypad Buttons - Each keypad button provides the Acclaim Camera Handpiece fingertip control over the PC streaming video capture software via the gameport cable. The specific functions performed by the keypad buttons depend on system hardware and software installation configurations that support a 2-button footswitch. Typical keypad actions provided below.
CONTROL MODULE CONTROLS AND CONNECTORS POWER INDICATOR LAMP Control Module A5050 Front Panel CAMERA Connector A 10 pin connector socket that accepts connection of the keyed 10-pin quick disconnect plug end from the multi-conductor Handpiece cable. Makes connection between the Camera Handpiece and Control Module to provide power, video output and control for the camera.
SYSTEM INTERCONNECTIONS A5000 Acclaim System - The diagram below shows the possible interconnections of the A5000 Acclaim System using the A5050 Control Module (without internal capture card). The heavy solid connection lines designate the typical operating configuration (connected to a computer system). The dashed line shows the optional connection to a video monitor, while the lighter solid connection lines show camera and power connections common to all system setups.
INSTALLATION DO NOT TWIST OR TURN THE CABLE CONNECTORS. EACH CONNECTOR IS KEYED AND MATES STRAIGHT ON WITH ASSOCIATED DEVICE CONNECTOR. NOTE: In addition to the supplied 15-foot multi-conductor cable, optional 6, 9, 30 and 50-foot lengths are available from your authorized Air Techniques Dealer at an extra cost. Camera Handpiece Connection - Carefully connect the supplied Camera Handpiece Cable between the Camera Handpiece and Control Module as follows: 1.
INSTALLATION Control Module USB Video Connection Options - Refer to corresponding figure below and perform the following procedure to connect the USB 2.0 High Speed Video output of the Acclaim Control Module to the associated PC computer as desired. 1. Connecting Directly to PC. Connect the supplied 6-foot USB 2.0 high-speed cable between the USB connector located on the rear of the Control Module to be connected and directly to the USB 2.0 high speed port on the computer. 2. Connecting via High Speed Hub.
INSTALLATION WDM Driver Installation - The supplied CD provides the WDM drivers needed to communicate between the Acclaim Camera System and the associated user-supplied USB streaming video software application installed on the PC computer system. Install the WDM drivers for the corresponding operating system (Windows 2000 or Windows XP) by performing the following procedures. Installing Driver Files Under Windows 2000: 1. Insert the supplied CD into the CD-ROM drive on the PC.
INSTALLATION Video Connection Options - Make connections as required by individual office equipment to connect the Acclaim Camera System video outputs. 1. S-Video. Using an optional 6-foot S-Video, 4-Pin Mini DIN/4-pin Mini DIN cable (PN 77379), connect between the S-VIDEO connector located on the rear of the A5050 Control Module and the associated connector of a video monitor or a computer with a capture card as required. 2. Composite Video.
INSTALLATION THE CAMERA HANDPIECE KEYPAD BUTTON OPERATION CONTROL MAY BE USED IN PLACE OF THE FOOTSWITCH THAT IS SUPPLIED WITH USER-SUPPLIED PC VIDEO CAPTURE SOFTWARE APPLICATION SUPPORTING A GAMEPORT-CONNECTED FOOTSWITCH. THIS FEATURE MUST BE USED ON A PC WITH AN INTERNAL GAMEPORT OR WITH AN OPTIONAL EXTERNAL A5125 GAMEPORT TO USB ADAPTER.
INSTALLATION 2. Connection without gameport made via optional external A5125 gameport to USB adapter cable a. Connect USB connector end of the A5125 adapter to the USB port on the rear of the PC. b. Set the red DIP switch on DB-15 connector of the A5125 USB adapter to the Joystick A (option 2) position. c. Turn on Computer and observe that the A5125 USB adapter is recognized. d. Connect 8-Pin Mini DIN connector end of the PC Game Port Control cable to the PC connector on the rear of the Control Module. e.
INFECTION CONTROL SHEATH MAKE SURE TO USE A NEW DISPOSABLE INFECTION CONTROL SHEATH (PN A5123) FOR EACH PATIENT. NOTE: For optimum image clarity, the optically clear section of the sheath must be aligned with the camera lens by facing the camera/lightsource section of the handpiece down toward the paper layer. Disposable Sheath Installation - Install a new infection control sheath on the Camera Handpiece for each patient as follows: 1. Remove the Camera Handpiece from the holder. 2.
FINAL SYSTEM CHECK Live Video Output Check - Upon activation, perform the steps below to check that live video is correctly displayed on the connected monitor for the applicable operating configuration. NOTE: If there is no video or if the video is not correctly displayed when connected to a computer system, contact your software provider to verify that the proper Windows operating system service pack is installed and the video capture software is configured for optimum performance.
FINAL SYSTEM CHECK 8. Reset the driver's video settings by performing the following: a. On the AMCAP screen, click OPTIONS on the menu bar along the top of the screen and select VIDEO CAPTURE FILTER from the drop down list. b. On the Properties screen select the VIDEO PROC AMP tab and then click the DEFAULT button. The image colors should now be correct. Click OK to close the Properties screen and exit from AMCAP application.
SYSTEM OPERATION Computer-Connected System Operation - The Acclaim Camera System A5000 is normally operated connected directly to a computer system running various PC USB streaming video capture software applications. In this configuration the camera provides the image/video source while the computer and associated software are used to display and save the resultant images. Perform the following procedures to operate the Acclaim Camera System when connected to a computer.
MAINTENANCE INSPECTION AND CLEANING Perform the following inspection and cleaning procedures periodically as a preventive maintenance measure to keep the Acclaim Camera System in optimal condition resulting in trouble-free operation producing crisp, clear images. DO NOT ATTEMPT ANY INTERNAL SERVICE OF ACCLAIM CAMERA SYSTEM COMPONENTS. CONTACT YOUR LOCAL AUTHORIZED AIR TECHNIQUES DEALER FOR SERVICE. FAILURE TO HEED THIS WARNING MAY RESULT IN EQUIPMENT DAMAGE AND VOIDING THE WARRANTY.
SPECIFICATIONS External Adapter Voltage input: 100-240 Volts ±10% Frequency: 50/60 Hz Voltage Output: 12 VDC (Optional adapter configurations available for international outlet usage.) Power Consumption: Video Outputs: Sensor: Format: Pixels: Resolution: Signal to Noise Ratio: Exposure Control: Illumination: Image: Viewing Angle: Operating Temperature: Storage Temperature: Humidity: Classifications: Protection for Ingress of Water: Flammable Atmosphere: 4.8 watts S-Video, Composite Video, High Speed USB 2.
ACCESSORIES The following lists the ordering number and description for accessory components available to maintain and expand the Acclaim Camera System to meet your professional needs. Contact your Air Techniques Dealer for information.
Air Techniques is a leading manufacturer of fine dental equipment from air and vacuum systems and X-ray film processors, to an impressive line of new products incorporating the most recent technological advances. These new products, vital components of the innovative dental practice, include intraoral cameras, air abrasion systems, rapid curing and bleaching systems, a digital imaging system which utilizes phosphor plate technology and, most recently, an intraoral X-ray system.