Installation guide

Internal DIP Switch Settings
5
Internal DIP Switch Settings
The CPE has a second four-bit DIP switch located internally next to the LEDs (see
figure below). This DIP switch sets the capabilities available to the external DIP
switch and allows flow control to be enabled/disabled. The ON position for the DIP
switch is down.
The following table lists the Internal DIP switch settings:
DIP SW Bit Function Description
1 Auto MDI-X ON: The external "MDI-X" DIP switch is disabled and Auto MDI-X is
available on the UTP port.
OFF: The external "MDI-X" DIP switch is enabled.
2 MAC learning
disable
ON: MAC learning function is disabled.
OFF: MAC learning function is enabled.
3 Flow Control
disable
ON: Disable flow control.
OFF: Enable flow control.
4 Link Pass
Through
ON: Enable Link Pass Through.
OFF: Disable Link Pass Through.
ON
1
2
3
4