Installation guide

Installing the FTTH CPE
8
Mounting the CPE
Caution: The EC3002 CPE is for indoor mounting only. Do not mount the unit on the
outside of a building.
The CPE includes rubber feet for desktop mounting.
Before you start installing the CPE, make sure you can provide the right operating
environment. Verify the following installation requirements:
Power requirements: 12 VDC via the included AC power adapter. Make sure that
a properly grounded power outlet is within 1.8 m (6 ft) of the CPE.
The CPE should be located in a cool dry place, with at least 5 cm (2 in.) of space
on all sides for proper air flow.
Place the CPE out of direct sunlight, and away from heat sources or areas with a
high amount of electromagnetic interference. The temperature and humidity should
be within the ranges listed in the specifications.
Make sure the fiber line is carefully routed to the CPE in a way that does not incur
a bending radius in the cable of less than 30 mm.
Be sure that the CPE is accessible for the UTP Ethernet connection.
Make sure UTP cable is always routed away from power lines, fluorescent lighting
fixtures and other sources of electrical interference such as radios, transmitters,
etc.
The status LEDs are clearly visible.
Wall mounting using the
wall-mounting slots
Desktop Mounting
Horizontal mounting using
rubber feet
Wall Mounting