Powered by Accton SIP Gateway VG3300 Series User Guide www.edge-core.
SIP Gateway VG3300 Series User Guide Update: 2005/06/20
VG3300 series user guide Contents 1. Safety Instructions ..................................................................................................................................................... 3 2. Preface ...................................................................................................................................................................... 3 2.1. What is SIP.....................................................................................................
10.10. 11. 12. Contact Address ...................................................................................................... 34 Other Parameters .................................................................................................................................................... 35 11.1. Dialing Plan ............................................................................................................. 35 11.2. Call Forward .................................................
VG3300 series user guide 1. Safety Instructions WARNING 1. Do not attempt to service the product yourself. Any servicing of this product should be referred to qualified service personnel. 2. To avoid electric shock, do not put your finger, pin, wire, or any other metal objects into vents and gaps. 3. To avoid accidental fire or electric shock, do not twist power cord or place it under heavy objects. 4.
are established using only the media capabilities that can be supported by all end points. Determine the availability of the target end point—If a call cannot be completed because the target end point is unavailable, SIP determines whether the called party is already on the phone or did not answer in the allotted number of rings. It then returns a message indicating why the target end point is unavailable.
VG3300 series user guide SIP Clients SIP clients include the following: Phones—Can act as either a UAS or UAC. Soft phones (PCs that have phone capabilities installed) and SIP IP phones can initiate SIP requests and respond to requests. Gateways—Provide call control. Gateways provide much functionality. The most common one is a translation function between SIP conferencing endpoints and other terminal types.
3. Package Contents The VG3300 Gateway X 1 Power Cord X 1 Accessories for fixing support X 1 System CD-ROM X 1 5 IDC Connector X 4 RJ-45 Ethernet Cable X 1 RJ-11 Telephone Cable X 1 (For VG3310/3318) (For VG3310/3318) Rubber footer 4. Panel Descriptions 4.1.
VG3300 4.2. series user guide Rear Panel There is a button on the rear panel of gateway for special maintenance. Please don’t touch this button under normal operation.
5. LED Indicators LED Label Description 10/100 LNK/ACT On Link up Off Link down Flash Sending/Receiving Ethernet data packets 100Mbps LOOP/RING FXS FXO Device Alarm On (LNK is on) 100Mbps Off (LNK is on) 10Mbps On Off hook Off On hook Flash Ringing out On Line is active Off Line is inactive Flash Ringing in The red light “On” indicates that system has some problem; please contact your vender. Power “On” indicates that the power supply is working normally.
VG3300 series user guide 6. Connectors Ports Label Description Voice Ports FXS Connects to a telephone set or fax machine FXO Ethernet Connects to the phone line LAN/Internet RJ-45 connector Ports MDI-X connects to a Modem PC RJ-45 connector MDI connects to a PC Console Port Console RJ-45 connector/RS-232 Interface (Only VG3306/3310/3318) 7. IDC Connectors (Only for VG3310/3318) IDC connector is used for the voice interface (FXS and FXO) on the frame model.
8. Information required before Installation You need to prepare the following information before installing the gateway. 8.1. IP Address The gateway requires an IP address for operation. Before installation you need to know how to obtain an IP address from your local ISP. Static IP, DHCP or PPPoE can be used. The following table helps you to decide what information you need. If your ISP offers static IP, you may need to obtain an IP from MIS personnel in order to prevent an IP conflict.
VG3300 8.2. series user guide SIP Information Before configuring SIP, the VG3300 requires SIP information for operation. The following table helps you to decide what information you need. Items Description 1. SIP Proxy If you want to make SIP calls through SIP proxy server, you will need to know the IP address or domain name of SIP proxy server. The proxy server is an intermediate device that receives SIP requests from a client and then forwards the requests on the client's behalf.
9. Installation and Configuration After preparing the information you need as specified in section 5, follow the following steps to do the basic configuration. You can use either a telephone or a system console to perform basic configurations. It is simple to connect a telephone set to FXS port and configures the system. If you want to use system console to configure the system (Only VG3306/3310/3318 support), you have to configure your VT100 terminal to match the settings of the gateway’s console port.
VG3300 series user guide 9.1.2. System console settings (Only VG3306/3310/3318) SIP-RG>enable SIP-RG #configure Enter configuration commands, one per line. End with CNTL/Z SIP-RG(config)#regional_id 07 SIP-RG(config)#exit SIP-RG#delete nvram This command resets the system with factory defaults. All system parameters will revert to their default factory settings. All static and dynamic addresses will be removed.
9.2.1. Static IP Mode The following table shows an example. IP Address 210.67.96.121 Subnet Mask 255.255.255.248 Default Gateway 210.67.96.120 Web Management 123 Password Using the information contained in the example above. The procedure is as follows: 1. Connect the gateway to a suitable Power source. 2. Connect a traditional phone set to the “FXS” connector located on the rear panel. 3. When the CPU/ACT light is on, pick up the phone to hear the dialing tone. 4.
VG3300 series user guide 2. Connect a traditional phone set to the “FXS” connector located on the rear panel. 3. When the CPU/ACT light is on, pick up the phone to hear the dialing tone. 4. ##0000 ; you should hear three short tones. 5. 011# ; the digit “0” is used to enable “manual” IP mode. 6. 15123# 7. 981# ; “123” is the web management password. ; Warm-restarts. 8. Hang up the phone. The system should now restart. You can also use console to configure IP address.
Mapping table of characters used in PPPoE. Example user name:83721@hinet.net,Password:123ab,The procedure is below 1. Connect the phone to the gateway 2. When CPU/ACT is light, pick up the phone and press ;You will hear 3 short tones. 3. ##0000 4. 0938333732314068696*465742*46*46574# ;Set user name:83721@hinet.net 5. 103132336162# ;Set password is 123ab 6. 981# ;Save and restart. 2.
VG3300 6. 010# ; “0” is to enable “manual” IP mode. 7. 02192*168*0*2# ; IP address. 8. 03255*255*255*0# ; Subnet Mask . 9. 981# series user guide ; Used to restart the gateway. 10. Hang up the phone to complete the configuration. Step 2:Configure IP address of PC Use the provided Ethernet cable to connect your PC to the port labeled “PC”, located on the rear panel of the gateway. For VG3306, VG3310, and VG3318, it is located on the front panel.
The “WEB” should gateway’s be all Capitals IP address (192.168.0. 2) On the PC that is connected to the gateway, enter the gateway’s IP address (Default 192.168.0.2) and press enter. The gateway will then prompt you with a dialogue box requesting that you enter a password. Use “WEB” (all capitals), for the User field and “123” for the password field that you have previously configured. Click the OK button; you should now have access to the gateway’s web based management interface page.
VG3300 1 Click “IP setting” to open this 4 2 display Click the “Apply” button to apply any changes.
6 Click the “Apply” button to apply any changes. 5 At this stage, your gateway should be able to use PPPoE to access the Internet. However, if you configured a wrong account number or password, your gateway cannot access the Internet. You are not able to use PC to access the gateway by using the IP address of 192.168.0.2 because the gateway has been set in PPPoE mode. You have to use phone set to configure the gateway back to fix IP mode (##0000 010#) and use PC browser to configure correct parameters.
VG3300 series user guide 10. SIP Configuration VG3300 not only can make regular PSTN calls, it also can communicate with IP Phones or Soft-Phones by using SIP protocol. Previous paragraphs have described the way to make regular IP calls. This section shows you what parameters you need to configure for SIP calls and how to make the SIP calls.
10.1. Channels and SIP entity Many Channels can be assigned as on SIP Entity. Single Channel also can be assign as on SIP Entity. Application example: As the figure below, Channel 1-3 belongs to SIP Entity 1: 001@edge-core.com. Channel 4 and Channel 5 belongs to SIP Entity 2: 002@edge-core.com. and Channel 6-8 belongs to SIP Entity 3: 003@edge-core.com. When other device under SIP network dial into 001@edge-core.com, the phone connect to Channel 1 is ringing.
VG3300 series user guide Notice: Each channel must belong to a SIP entity. 10.2. SIP Proxy and Register Parameters You need to configure IP address or Domain name of Registrar and Outbound Proxy server, please check the information is right. SIP service provider will give you an IP address or Domain name of Registrar and Outbound proxy when you apply for the service. Configuration WEB Page: ADVANCED\SIP COMMOM Notice: The Registrar Server is only for SIP entity registering.
10.3. SIP Entity SIP service provider will assign one or more SIP accounts for you when you apply for the service. In standard, the SIP account is called ‘Public Address’, so you need to configure the account information in ‘Public Address’ item. The format is like an E-mail address such as mary@edge-core.com. The Public Address will be generated automatically with the format below if user keeps the Public Address empty. "Default account's username" @ "Registrar" if you had enter the information below 1.
VG3300 series user guide "Realm" is a kind of verification for SIP Outbound Authentication. If SIP service provider does not provides this information. The gateway will create a default Realm (by string USER-UNSPECIFIED-REALM) automatically with your Username and Password mentioned on last section for SIP Outbound Authentication. If there are more than one SIP entity is registered on this gateway. The gateway creates Realm for each entity.
After configuring the parameters of STUN, please act Warm-Restart. Configuration WEB Page: ADVANCED\STUN You can enable and disable the service on WEB page. The STUN refresh time defines how long the device will send a binding request packet with discard flag on to STUN server. A binding packet with discard flag off will be sent each time when the number of binding request packet with discard flag on reach the Rebinding counts.
VG3300 series user guide 10.6. Check SIP entity Status You can use the WEB page to check the SIP entity is registered successful or unsuccessful.
If the status shows “REGISTERED” means successful, otherwise means fail; please notice that. When you find the registration is fail, first check the “Registrar Setting” configuration is normal, or not “Enable”. Then check the “Public Address” and “Outbound Authentication” configuration is in normal status. If the configurations are all right, please check the situation with your SIP service provider. 10.7. Phone Book 10.7.1.
VG3300 series user guide rings immediately when FXS channel user of VG3300 picks up hand-set. ♦ If the FXS channel is Hotlined to VES-3302 Line, FXS channel user of VG3300 hear dialing tone from VES3302 when pick up hand-set, and then he/she can dial extension number to other SIP device.
Hotline mapping table Channel (FXS) only Index Number Description 1 FXS channel 1 Index number “1” maps the 1st FXS channel 2nd FXS channel 2 Index number “2” maps the 2nd FXS channel …. …. … 16th FXS channel 16 Index number “16” maps the 16th FXS channel st Available Hotline index number Model Available Hotline Index Number Note VG3306 1, 2, 3, 4 VG3310 Depends on module used. Please refer to Only FXS channel can be table below.
VG3300 300 Jason@fwd.pulver.com 5060 series user guide Yes User of 1st FXS channel picks up hand set, and then 01@61.220.145.70 rings immediately User of 2nd FXS channel picks up hand set, and then 73797@fwd.pulver.com rings immediately Hotline to VES3302 Assume the Public Address of VES3302 is 1234567@61.220.145.70 and it has extension number 1001 to 1002. 1002 SIP Phone (Notebook) VES3302 Entity: 1234567@61.22 0.145.
3. If the number is not in dialing plan, the call will be sent to PSTN. Phone Book Call: Dial <#>+ +<#>. 1. Compare SIP Phone books; check the number if it is in phone book. 2. If the number is configured in Phone Book and Proxy selection is set to "No", you will hear a busy tone. If Proxy selection is set to "Yes", then send the call to proxy. 3. If the index number you had configured to use Via Proxy but it communicates with proxy failed, you will hear busy tone. 4.
VG3300 series user guide Please enable Auto Answer configuration at WEB Page: CHANNEL If you don't enable the Auto Answer configuration, the inbound call from PSTN will be assigned to a free FXS port of this gateway directly. It makes Inbound Transit Call impossible. When Auto Answer function is enabled, the gateway will answer the call and calling side will hear the second dial tone. For the Auto Answer function, it is also divided into Enable and Enable w/ Pincode options.
Notice for the Inbound Transit Call 1. If the SIP number that user dial does not match any prefix code configured in Dialing Plan page, the call is disconnected. 2. If the PIN code does not match any passwords configured in Password For Inbound Transit page, the call is terminated. 3. If the Index Number does not match any pre-configured Phonebook Index in Phone Book page, the Index Number will be regarded as SIP number and create a IP call without applying any match rule configured in Dialing Plan.
VG3300 series user guide 11. Other Parameters 11.1. Dialing Plan X means all calls will be sent to SIP proxy, if the SIP call is fail, it is disconnected. Only if Outbound Proxy is disabled, then the gateway will try to connect the number by PSTN. Outbound Proxy Setting can be configured on Web Page: SIP Common. Please refer to 12.
limit user to dial certain number. The rules below explain the judgment. 1. System will check the dialing plan on last page in advance to decide whether it is PSTN call or SIP call. 2. If the call will be send to SIP Proxy, then system will exams the number to see if it meets Rewriting Rule. 3. If the SIP call does not meets any Rewriting Rule, system will build the SIP call with the number that user dials. 4.
VG3300 series user guide If the prefix number dials from user are 1~9, then add x 8862x 8862 in front of the original number. For example, if user dials 82263368, then the system dials 886282263368 to built SIP call. 0204 ! If the prefix number dials from user are 0204, then the call is terminated. Matching Rule 1. Best Match rule, the longest digits match first. 2. Wildcard ( x digits) match last 11.2. Call Forward There are three forward types: 1.
WEB page: ADVANCED\SIP COMMOM Phone Set: Please refer to section Appendix A: Phone-Set Command.
VG3300 series user guide 11.3. Inbound Authentication You need to configure inbound authentication if you request authentication for other SIP phone to call you. Configuration WEB Page: ADVANCED \ SIP INBOUND AUTHENTICATION 11.4. FAX For VG3300 software version 1.05 or above, SIP-based T.38 Fax protocol is applied. Any brand SIP gateway with SIP-based T.38 Fax protocol can transmit FAX with each other. T.38 is FAX protocol and it has better performance and better successful transmission rate.
both sides support SIP-based T.38. Note: If VG3300 connects different SIP devices, some have T.38, but some use G.711 codec only, then user should enable G.711 codec support for FAX. Setup method is listed below: 1. The same step as above set Connect Device to Fax 2. Setup “Codecs Type“, Web Folder: ADVANCED\SIP COMMON Select and mark “PCMU” and “PCMA” Codecs (G.
VG3300 3.
11.5. Non-SIP Call port seizure preference For non-SIP Calls, the port seizure preference is listed below 1. Inbound from PSTN If the inbound FXO port was configured as "Fax" device, it will also seize only FXS ports that "Connect Device" is configured as Fax. The Voice devices behave the similar way.
VG3300 series user guide call dials from B to D will not be busy. Here is the possible situation. D keeps talking with A and hears Call Waiting Tone if B calls D. B hears normal ring back tone without sense any different.
Connection Type A: FXS port of VG3300 Series B, C: SIP Device (VG3300 Series, other brand SIP gateway. SIP phone...), Normal PSTN phone call (special condition is described below) Call waiting function works only on SIP call. So PSTN call works when it is transited as SIP call. If Inbound transit call is configured on VG3300 (please refer to 10.9 Make Inbound Transit Call), then Call Waiting function is available when user dials the SIP number of this VG3300 gateway itself.
VG3300 series user guide This selection ignores the source contact information (IP, port number) which VG3300 received. It always sends the RTP packet to the contact information (IP, port number) described in the packet (SDP) received. Send RTP to 10.13.6.18 port: 4000 VG3300 Series (192.72.83.23, port: 10000) Network SDP in Packet 10.13.6.
12. WEB MANAGEMENT INTERFACE The Tree Architecture of Web Management is shown below HOME BASIC GENERAL IP SETTING ADVANCED General SIP COMMON SIP OUTBOUND AUTHENTICATION SIP INBOUND ATHENTICATION STUN Dialing Plan Inbound Transit (for gateway has FXO port.
VG3300 12.1.
Category Section Description Default Setting Information Region ID Display region ID.(Read only) 0 Software Display software version.(Read only) Version BootRom Display BootRom Version.(Read only) Version Hardware Display hardware Version.(Read only) Version Card Type Display card type. (Read only) Up-Time Display the use time since from system reboot.(Read only) MAC Display MAC address.
VG3300 Daylight ON: Enable daylight saving. saving OFF: Disable daylight saving. Auxillary Signaling UDP port to transfer signal packets. It protocol Port can be setting in the range of 0 to series user guide OFF 0 65535. (Must reboot system to apply changes)(Only support VG and VTG devices) RTP Base of UDP port to receive RTP Base Port packets. It can be setting in the range of 4000 0 to 65534.
12.2.
VG3300 Current Setting series user guide Display the configured IP 192.168.0.2 address, subnet mask address 255.255.255.0 and default gateway. (Read 192.168.0.1 only) Change To Enter the IP address that will be used after next restart, Including: IP Address Subnet Mask Address Default Gateway (This item is used only on Manual mode of IP Setting.) PPPoE Account Settings The user’s account of PPPoE protocol, provided by ISP. Password The user’s password of PPPoE protocol.
12.3. ADVANCED / GENERAL Category Section Description Default Setting Flash Button Flash Time System confirmed 200 msec “Flash” time. Touch Tone (DTMF) Duration The duration to send a 100 msec DTMF. Inter-digit The inter-digit time of 100 msec sending string of DTMF digits. Guard Time Line The time defines how 0.8 sec long the system will not take incoming call after call has been disconnected.
VG3300 series user guide number if a ‘#’ digit is missing. Redundancy Number of times to retry T.38 Fax protocol. Use more Redundant packet when network is unstable. T.38 Fax Relay No Redundant packet 1 Redundant packet 2 Redundant packets 3 Redundant packets 4 Redundant packets Busy Tone Spec Frequency f1, f2 (300 ~ 3000Hz) Cadence on, off. The on and off (100 ~ 5000ms) duration in playing the tone Reorder Tone Spec Frequency f1, f2 (300 ~ 3000Hz) Cadence on, off.
12.4.
VG3300 series user guide Section Item Field Description Port and Header Port The control port number of SIP protocol. 5060 Header Select ‘Standard’ or ‘Compact’ to be the Standard header format of SIP packet. When Form Default Compact is selected, the header will be shorter and it saves bandwidth. Outbound Proxy Domain Setting Name Registrar Setting Out-band DTMF Domain name or IP address of proxy. Empty Disable Port Control port number of SIP protocol.
Section Item Field Description PCMU: Mark the selection to Enable Default Enable PCMU Codec (G.711 u Law) PCMA: Mark the selection to Enable Enable PCMA Codec (G.711 A Law) SIP Entity Codec You can select the codec priority for G729-G723-P Priority your requirement. CMU-PCMA SIP Entity Select an entity and click Select button 1 to display follow items’ setting of SIP entity section.
VG3300 Section Item Field Description series user guide Default Default Account information for registering SIP Account Proxy Username: It may the same as your SIP number Password: Password for Authentication Confirm Password: Reconfirm Password Contact Address Setting Current Display current setting of Setting Contact Address.
Section Item Field Description Entity Default Show ‘+ ‘ means the SIP entity is for the Empty channel. 12.5. SIP OUTBOUND AUTHENTICATION Section Item Field Description SIP Outbound Maximum Maximum number of entries (Read Only) 50 Authentication Default allowed Entered Number of entries of (Read Only) 0 authentication entered.
VG3300 Section Item Field Description List series user guide Default Entity: Which entity that you select. Realm: Domain name or IP address. Username: Username of authentication. The gateway creates default entry according to the Public Address Setting for easy registration. Please refer to 10.3 SIP Entity and 10.4 SIP Outbound Authentication Update Enter the information of outbound Entry authentication Empty Entity: Select an entity. Realm: Domain name or IP address.
12.6. SIP INBOUND ANTHENTICATION Section Item Field Description SIP Inbound Realm Enter domain name, IP address or word Empty Authentication Default string. Maximum Maximum number of (Read Only) 20 entries allowed Entered Number of entries of (Read Only) 0 authentication entered. Entries List Display the entries (Read Only) Empty Entity: Which entity that you select. Username: Username of authentication.
VG3300 Section series user guide Item Field Description Default Update Entry Enter entries of authentication Empty Entity: Which entity that you select. Username: Username of authentication. Password: Password of authentication. Confirm Password: Enter password again for confirmation. Delete Entry Delete entries of authentication Entity: Which entity that you want to delete. Username: Username of authentication. 12.7.
Section Item Field Description Default DIALING PLAN Maximum Maximum number of (Read Only) 100 entries allowed Entered Number of entries of (Read Only) 1 authentication entered. List Display the entries (Read Only) x The default value “x“ means that all numbers that you dial will first go through SIP proxy. Dial In Rewriting Add Dialing Plan Enter numbers. Example: 050. Empty Delete Entry Enter numbers for delete.
VG3300 series user guide 12.8. Inbound Transit Only VG3300 gateway with FXO port has this web page. Group Field Description Transit call Warning Time This gateway will send warning tone periodically to 60 Default Value check if the line is still alive. If calling side fail to press any key after hearing the warning tone, the line will be disconnected. Release Call by This gateway will check the RTP packet Checking RTP 0 periodically to verify if the line is still alive.
Group Field Description Default Value Add Passwords Enter a new password, any combination of digits Blank (0~9), less than 9 characters. The password will be used at PINcode for auto answer function Delete Passwords Enter the password to be deleted, refer the detail Blank data under Entries List 12.9. STUN Section Item Field Description STUN Server Control Enable or Disable STUN Server service.
VG3300 Section Item Field Description NAT WAN IP Address Input this NAT WAN IP helps you to pass series user guide Default through NAT without using STUN server. The port number inside and outside NAT should be the same. NAT WAN IP is the Public IP that used on NAT device Note: If you disable STUN server and input NAT WAN IP here, the RTP (normally 4000) and Signaling (normally 5060) port number inside and outside NAT must be the same, and Server Port need to be configured on NAT device.
12.10. CHANNEL Category Section Description Default Setting Information Channel Channel number: Channel Display port type. (Read only) Type Phone: FXS Interface, connect to telephone set or Fax machine. Line: FXO Interface, connect to phone line.
VG3300 series user guide Enable Channel For FXS port: Control Bothway: Can make and accept IP call and PSTN call from this channel Disable Disable all functions of this port. For FXO port: IN_Only: Accept calls from PSTN only Bothway: Accept call from PSTN or call dial from FXS Disable: Disable all functions of this port. Current State Display the current state of this port. (Read only) Enable/ Disable.
Battery This mechanism will reverse Reverse the polarity promptly that help OFF some PBX to identify the start and end of each call ON: Enable the function OFF: Disable the function Auto Answer This unit auto answer the call Disable from FXO Disable: Disable Auto Answer Enable: Enable Auto Answer Enable w/ Pincode: Enable Auto Answer and Pincode verification.
VG3300 series user guide 12.11. PHONE BOOK Section Item Field Description Apply to Hotline Control Default Enable or Disable the hotline function to Disable VES-3302 Line or other SIP device to make hotline call. SIP Phone Book Maximum Maximum number of entries (Read Only) 200 allowed Entered Number of entries of phone (Read Only) 0 books entered. Entries Display phone books List Index: Dialing number Public Address: SIP account. Port: Port number. Via Proxy: Via proxy or not.
Section Item Field Description Default Update Enter entries Empty Entry Index: Enter dialing number Public Address: Enter SIP account. Port: Enter port number Via Proxy: Select via Proxy or not Delete Delete entries Empty Entry Index: Enter the index for delete. 13. Use Private IP (Behind NAT) Using a Private IP in a NAT Environment The gateway is able to communicate with other gateways under a NAT environment using Private IP addresses on the LAN side of your IP Sharing device.
VG3300 14. File Management 14.1. File Types The naming convention to the file type of VPS3302 is listed in the following table: File Name SIP3302.CFG SIP3304.CFG SIP33XX.CFG SIP3302.RUN SIP3304.RUN SIP33XX.RUN SIP3302.WEB SIP3304.WEB SIP33xx.WEB File Type Description System configuration file File of system configuration Executing file System Software Web file Page for web browser 14.2. Software Update 14.2.1. Software update via FTP Preparation before Updating FIRMWARE 1.
Software Update by FTP for File Type RUN and WEB 1. Execute FTP Client Software, e.g. CuteFTP Enter IP Address, User Name (default is FTP), Password (the password of FTP and Console is same, and the default is blank), and the Port Number to 21 2. Click button Connect to get connection between gateway and FTP Client. The files of the gateway will be displayed on the window if the connection is successful.
VG3300 3. series user guide Select the file with extension of .RUN and click button Upload and then Yes to overwrite. (Please notice that the file name must be same as the file name in the Gateway, e.g. SIP3304.RUN). 4. After the file is overwritten (you may check if the time of the file is updated), Gateway has to run Cold Start to store the configure file, then the updating is effective. 5. Select the file with extension of .
15. Appendix 15.1. Appendix A: Phone-Set Command Pick up the handset and listen for the dialing tone. Dial “##0000 and listen for three consecutive tones before setting the following parameters. After input the parameters, please dial ‘# to end the configuration.
VG3300 Password 16 Change FTP 6 digits Password 40 Listen for the IP (ending ”#” is not required) Address 41 Listen for the Subnet (ending ”#” is not required) Mask 42 Listen for the Default (ending ”#” is not required) Gateway 46 Listen for WEB, FTP, 1:FTP; 2:HTTP 3:Telnet Telnet Port 47 Listen for Current (ending ”#” is not required) Public Address 95 Region ID 2 digits 97 Reset unit to Factory 1: reset all; 2: keep IP Default values 98 System Warm Restart 1: do it 75 series use
15.2.
VG3300 15.3. Specifications Voice Interface Loop start, 2 wire FXS interface Feeding Voltage: 20V Feeding Current: 30 mA FXO interface Connectors Loop start, 2 wire RJ-11 Connectors (3304/3306) IDC Connectors (3310/3318) Voice compression G.711/G.723/G.729AB Silence suppression VAD, CNG Echo cancellation G.165/G.
15.4.
VG3300 V 56 W 57 series user guide 15.5.
VG3306 V 56 W 57 series user guide 15.5.