User's Manual Part 7
ProScale M150, M250 and all products with General Purpose LCD Digital Displays 38 of 38
Programming Summary
Programming Factory Works with Digital Display:
Parameter Function Default Basic 2AA 2D 24VDC
Pr0 Encoder Direction 0 ◙ ◙ ◙ ◙
Pr1 Segment Offset 1 - On ◙ ◙ ◙ ◙
Pr2 High Speed ReadHead 0 - Off ◙ ◙ ◙ ◙
Pr3 Zero, Offset Entry 1 - Enable ◙ ◙ ◙ ◙
Pr4 Display Resolution 1 - Normal ◙ ◙ ◙ ◙
Pr5 mm or cm 0 - mm ◙ ◙ ◙ ◙
Pr6 Fractions, mm, in 0 - all ◙ ◙ ◙ ◙
Pr7 Scaling 1.000 (none) ◙ ◙ ◙ ◙
Pr8 Auto off 15 - 15 min. ◙ ◙ ◙ ◙
Pr9 Auxiliary Keypad 7 - all keys ◙ ◙ ◙
Pr10 Offset Addition 0 - disabled ◙ ◙ ◙
Pr11 Offset Addition 1 1.000 Inch
◙ ◙ ◙
Pr12 Offset Addition 2 1.500 Inch ◙ ◙ ◙
Pr13 Offset Addition 3 2.000 Inch ◙ ◙ ◙
Pr14 Output Mode 0 - drift ◙
Pr15 Output Polarity 0 - N/O ◙
Pr16 Lower Limit 0.000 ◙ ◙ ◙ ◙
Pr17 Upper Limit 5.000 Inch ◙ ◙ ◙ ◙
Pr18 Drift Tolerance .01 Inch ◙ ◙ ◙
Pr19 Auto Monitor ON 0 - disabled ◙ ◙ ◙
Pr20 Auto Monitor OFF 0 - disabled ◙ ◙ ◙
Pr21 Auto Monitor Distance .500 Inch ◙ ◙ ◙
Pr22 Backlight On 1 - 3 seconds ◙
Pr23 FUTURE FEATURE 1
Pr24 FUTURE FEATURE 0
Pr25 FUTURE FEATURE 0