User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  14 of 44 
Connector Link 
Guide Clip
Installation 
1.  Note  the  orientation of  the  readhead on  the  scale.    Be  sure  the  arrow  on  the 
readhead points towards the “BLACK END OF SCALE”. This orientation is critical 
for proper operation of ProScale.  Be sure the mounting location for the readhead 
and scale will allow this orientation. Take care when sliding the readhead onto the 
scale  so  the  brass  “fingers”  inside  the  readhead  do  not  get  damaged.  (A  slight 
“wiggling”  motion  when  installing  the  readhead  on  the  scale  will  simplify  the 
process.) 
2.  Determine an appropriate mounting location for the system.  Most applications of 
the  Model  150  will  have  the  readhead  held  stationary  while  the  scale  is  passed 
through the readhead.  The ProScale will also operate properly if the readhead is 
moved along the scale (see figures on next page). 
3.  If the readhead is to be mounted stationary, the scale should be 
attached to a moving part of the measuring application or machine 
using the Connector Link. 
Mount the readhead using three screws or bolts. Mount one end of 
the connector link to the scale using an M5 (or 10-32) screw and the 
other end to the moving part.  Check that the scale is properly 
aligned with the direction of motion of the moving part.  Be sure 
both connections are secure or inaccurate/erratic readings 
could result. (The connector link compensates for small 
misalignments of the installation and acts as a shear pin). The connector link must 
be mounted in the same direction as the scale (see figure below). 
Note: Failure to use the connector link could void the warranty. 
4.  If you choose to hold the scale stationary and move the readhead to measure, you 
should use the Guide Clip to move the readhead along the scale 
(see figure on next page). The connector link is not necessary in 
this configuration.  
Mount the scale using a M5 (or 10-32) screw. Be sure the scale is 
properly aligned as the readhead is moved (the Guide Clip will 
compensate for slight misalignment in one direction only). Adjust 
scale alignment if necessary. 
For accurate measurements, the guide clip must be mounted 
perpendicular to the direction of travel of the readhead. The guide 
clip should exert some pressure over the full range of travel on the readhead so the 
two move as a single unit. 
Note: Failure to use the guide clip could void the warranty. 