User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  18 of 44 
Guide Clip
Installation 
1.  Note  the  orientation of  the  readhead on  the  scale.    Be  sure  the  arrow  on  the 
readhead points towards the “BLACK END OF SCALE”. This orientation is critical 
for proper operation of ProScale.  Be sure the mounting location for the readhead 
and scale will allow this orientation. Take care when sliding the readhead onto the 
scale  so  the  brass  “fingers”  inside  the  readhead  do  not  get  damaged.  (A  slight 
“wiggling”  motion  when  installing  the  readhead  on  the  scale  will  simplify  the 
process.) 
2.  Determine an appropriate mounting location for the system.  Most applications of 
the  Model  250  will  have  the  scale  held  stationary  while  the  readhead  is  moved 
along the scale. However, the ProScale will read correctly if the readhead is moved 
along the scale or if the scale is moved through the readhead. 
3.  When the scale is stationary and the readhead moves to measure, you should use 
the Guide Clip to move the readhead along the scale (see figures on next page). 
Mount the scale using M4 (or #8) screws.  Be sure the screw heads do not protrude 
above the surface of the extrusion.  Check that the scale is 
properly aligned as the readhead is moved over its length (the 
Guide Clip will compensate for slight misalignment). Adjust scale 
alignment if necessary. 
For accurate measurements, the guide clip must be mounted 
perpendicular to the direction of travel of the readhead. The guide 
clip should exert some pressure over the full range of travel on the 
readhead so the two move as a single unit. 
Note: Failure to use the guide clip could void the warranty. 
4.  The Digital Display may be mounted in a location which allows for easy viewing by 
the operator.    The location of all parts  should  also safeguard  the cable  from 
possible damage.  ProScale wiring should be kept away from electrical wiring and 
motors.    Plug  the  readhead  into  the  display.    See  Section  4:  Digital  Display 
Operation 
Note: If any other mounting method is used, observe the following: 
A.  Do not drill through the green portion of the scale at any point over which the 
readhead will travel. 
B.  Do  not  mount  the  scale  so  the  mounting  hardware  interferes  with  the 
movement of the readhead. 