User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  25 of 44 
ON/OFF
Momentarily pressing  the  ON/OFF  key  will cause  the  display  to  turn  on  or  off.  The 
Firmware Version is displayed on power-up or when ON/OFF key is pressed.  While on, if 
no  key  presses  or  positional  changes  occur  within  15 minutes,  the  Digital  Display  will 
automatically  turn  itself  off  to  conserve  battery  life.    While  off,  if  a  position  change  is 
detected  (.05mm  or  .002in)  or  the  ON/OFF  button  is  pressed,  the  display  will 
automatically turn itself on with no loss of measurement information.  
(Programming Parameter Pr8. Factory default set to 15 minutes.) 
Battery voltage is displayed by pressing and holding the ON/OFF key for 5 seconds while 
display is turned on. 
CAUTION: Pressing and holding the ON/OFF and MODE key for 10 
seconds while the display is turned off will perform a full segment LCD 
test AND re-set all programming parameters to factory defaults
MODE 
The digital display can show measurement information in Imperial or Metric.  To change 
the current display mode, momentarily press the MODE key.  With each key press the 
display  will  cycle  through  decimal  inches,  fractional  inches  (1/16),  (1/32),  (1/64)  (If 
enabled  by  Programming  Parameter Pr6)  and metric (mm or cm based  on setting of 
Programming Parameter Pr5). 
When  the  display  is  in  a  decimal  mode  (mm,  cm  or  in)  it  will  auto-range  to  the  next 
resolution if the value is displayable in the next range.  This allows the display to be used 
with  Mitutoyo  Digimatic®  products  in  inch  mode  or  different  resolutions  other  than  2 
decimal places. 
When the display  is in 1/16 or 1/32 inch fraction mode, a series of “bars” in the upper 
right corner of the LCD each represent an additional 1/64th of an inch measurement.  ie. 
When  in  1/16  inch  mode  and  three  bars  are  showing,  the  measurement  displayed  is 
rounded down to closest 1/16 inch and each illuminated bar indicates an additional 1/64 
of an  inch  (“heavy”)  measurement.  For better resolution  switch to 1/32 or 1/64 fraction 
mode. For the best resolution switch to a decimal mode. 
When the measurement is greater than +  99 63/64 inches, a +100 or +200 will show in 
the upper right portion of the LCD to indicate this amount must be added to the displayed 
reading. ie: if the measurement is 154 5/8 inches, 54 5/8 and +100 will be displayed on 
the LCD.  If  the measurement  is -307  23/64  inches - 7  23/64 ,  +100  and +200  will be 
displayed on the LCD. 
The Resolution of the display can be set for Normal; (.01mm or .001in), Reduced; (.1mm 
or .01in) or Increased; (.01mm or .0005in) (Programming Parameter Pr4.) 