24VDC Operation 
The 24VDC Digital Displays have some additional functions that are not available on 
battery powered displays.  
The 24VDC displays are designed to run on DC voltage ONLY. 
DO NOT ATTEMPT TO OPERATE THESE DISPLAYS USING AC VOLTAGE 
Surface Mount Above,  
Panel Mount Right 
Limit/Monitor Signal Output 
This function is available on 24VDC powered Digital Displays ONLY. 
A connector provides a solid-state output (.1A / 30 VDC) that can be configured to 
activate on either a position drift (MONitor) condition or a measurement limit (LIMIT) 
error. The output can be configured for normally open (N/O, not conducting to ground) or 
normally closed (N/C, conducting to ground). Although the Digital Display LCD flashes 
when either a position drift (MONitor) condition or a measurement limit (LIMIT)error is 
encountered, the output signal only changes state once for out of limit condition and then 
toggles back when an in limit condition is restored. 
For additional programming information see Limit Mode above and MONitor Mode below. 
Caution: These functions are active during Display Programming. If their parameters are 
changed during programming the output signal could become active. 
(See Programming Parameters 9, 14 and 15. Factory default is MONitor, N/O.) 
Backlighting 
This function is available on 24VDC powered Digital Displays ONLY. 
LCD backlighting can be configured to always remain OFF, to always remain ON or to 
come on when any key is pressed and remain on for 3, 7 or 15 seconds. 
(See Programming Parameter 22. Factory default is on for 3 seconds.) 