User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  30 of 44 
MONitor 
The  Digital  Display  has  the  ability  to  monitor  a  position  to  detect  position  drift  or 
measurement variance.  To activate the monitoring mode, position the readhead to the 
desired location and momentarily press the MON key.  The MON symbol will flash on the 
display to indicate that the position monitor mode is active. 
If the readhead moves outside the programmed tolerance the displayed reading flashes, 
indicating a drift condition.  When the readhead is moved back within the programmed 
tolerance, the displayed reading will stop flashing. 
To exit the monitor mode, momentarily press the MON key.  The MON symbol will stop 
flashing and the currently displayed position will also stop flashing. 
NOTE:  Position monitor mode can only be activated while in the ABS measuring mode. 
If the ABS/INC key  is  depressed  while monitoring, the position-monitoring  mode is 
automatically exited.  
The display can be programmed to automatically enter or exit the MONitor mode based 
on elapsed time or movement of the encoder. 
If the programmable auto monitor is enabled (Programming parameter Pr19 set to 1), the 
Digital Display will automatically enter monitor mode after either 30 or 60 seconds of no 
encoder motion. If the programmable auto monitor is disabled, the ProScale will 
automatically exit monitor mode if the encoder is moved beyond a programmable 
distance from the monitored position. This option, in conjunction with auto monitor 
activation, allows the ProScale to be kept in monitor mode without manually pressing the 
monitor key. 
(See Programming Parameters 19,20, 21.  Factory default is OFF.) 
SEND 
The  Digital  Display  provides  an  output  port that  can  be  used  to  send  measurement 
information to a compatible SPC device such as a printer or data acquisition unit.  After 
connecting the SPC device to the 10 pin connector on the display, the user may initiate 
the  data  transmission  by  momentarily  pressing  the  SEND  key.    This  signals  the  SPC 
device to acquire the data from the digital display. 
Pressing the SEND key displays “ Snd ” on the display for 1 second to show activation of 
the send function (even if no SPC device is attached to the ProScale). 
The data format and connector style of the ProScale SPC output is the same as Mitutoyo 
SPC.  This is  an industry standard  that  can be  interfaced  with  most available  SPC 
products including multiplexers, RS232 converters and PC plug-in boards. Data from the 
ProScale is sent to the SPC connector in either millimeters or decimal inches, whichever 
is currently displayed on the LCD. 
If no SPC device is attached to the display, the SEND key has no other function. 
See Section 6 Accessories for interface and data acquisition products descriptions. 
F1 / F2 
These keys are used for special features and/or Custom programming functions.   