User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  34 of 44 
Pr15 – Output Polarity  [0, 1].  
Used to configure the signal output. N/O or N/C in relation to circuit ground. 
0 = N/O, the output is Normally Open (not conducting to ground). 
1 = N/C, the output is Normally Closed (conducting to ground). 
Pr16 – Lower Limit [-999.999 to 999.999in] or [-9999.99 to 9999.99mm] 
Sets the lower limit alarm value. Default = 0.000IN. 
Active only when parameter Pr14 = 1. Note: Default is set in Inches 
Pr17 – Upper Limit [-999.999 to 999.999in] or [-9999.99 to 9999.99mm] 
Sets the upper limit alarm value. Default = 5.000IN. 
Active only when parameter Pr14 = 1. Note: Default is set in Inches 
Pr18 – Drift Tolerance [.01 to 9999.99mm ] or [.001 to 999.999in]. 
Range of motion allowed (+ or -) while in MONitor mode. Default =. 01IN. 
Note: Default is set in Inches 
Pr19 – Automatic Monitor ON Time  [0, 1 or 2] 
Configures display to automatically activate MONitor mode after 30 or 60 seconds 
of encoder inactivity. 
0 = disabled. 1 = 30 seconds. 2 = 60 seconds. 
Pr20 – Automatic Monitor OFF Enable [0, 1] 
Configures display to automatically exit MONitor mode after a programmed 
distance (Pr21) has been exceeded from the drift tolerance position (Pr18). 
0 = disabled  1 = enabled. 
Pr21 – Automatic Monitor OFF Distance [0.001 to 999.999in] or [0.01 to 9999.99mm].   
The distance that must be exceeded from the drift tolerance position (Pr18) to 
activate auto monitor off. Default = 0.500in 
This parameter is relevant only when Pr20=1. Note: Default set in Inches 
Pr22 – Backlight ON time  [0, 1, 2, 3 or 4] 
The ON time of the LCD backlighting (24VDC displays only). 
0 = always off. 1 = 3 seconds. 2 = 7 seconds. 3 = 15 seconds. 4 = always on. 
Backlighting is activated when a key is pressed. 
Pr23 – Future Enhancement DO NOT CHANGE  [0,1,2]   Default =1 
Pr24 – Future Enhancement DO NOT CHANGE  [0..63]  Default =0 
Pr25 – Future Enhancement DO NOT CHANGE  [0..31]  Default =0 
CAUTION: Pressing and holding the ON/OFF and MODE key for 10 
seconds while the display is turned off will perform a full segment LCD 
test AND re-set all programming parameters to factory defaults