User`s manual
ProScale M150, M250 and all products with General Purpose LCD Digital Displays  37 of 44 
Programming Summary 
Programming          Factory    Works with Digital Display: 
Parameter   Function      Default      Basic  2AA  2D  24VDC 
Pr0     Encoder Direction    0               
Pr1     Segment Offset      1 - On               
Pr2     High Speed ReadHead  0 - Off             
Pr3     Zero, Offset Entry    1 - Enable             
Pr4     Display Resolution    1 - Normal               
Pr5     mm or cm        0 - mm               
Pr6     Fractions, mm, in     0 - all                
Pr7     Scaling        1.000 (none)             
Pr8     Auto off        15 - 15 min.           
Pr9     Auxiliary Keypad    7 - all keys              
Pr10   Offset Addition      0 - disabled           
Pr11   Offset Addition 1     1.000  Inch  
     
Pr12   Offset Addition 2     1.500  Inch            
Pr13    Offset Addition 3     2.000  Inch            
Pr14    Output Mode      0 - drift             
Pr15    Output Polarity      0 - N/O             
Pr16    Lower Limit       0.000              
Pr17   Upper Limit       5.000  Inch            
Pr18   Drift Tolerance      .01   Inch            
Pr19   Auto Monitor ON     0 - disabled           
Pr20   Auto Monitor OFF    0 - disabled           
Pr21   Auto Monitor Distance    .500  Inch             
Pr22   Backlight On      1 - 3 seconds           
Pr23   FUTURE FEATURE    1 
Pr24   FUTURE FEATURE    0 
Pr25    FUTURE FEATURE    0 