Installation manual
Operation Manual for LCD Digital Readouts  Page 12 of 48 
24VDC Operation 
The General Purpose and the Panel Mounted LCD Digital Readouts will 
operate on batteries or 24VDC. The General Purpose Readout uses a multi-
purpose plug-in connector for power as well as input and output signals. The 
Panel Mount Readout uses screw terminals for these connections. 
(Connections can be configured as outputs or inputs, but not both at the same 
time).   See Section 3: Circuit Board Jumpers 
General Purpose DRO 
Panel Mount DRO 
Notes: 
When powering Readouts with 24VDC the Scale and the Readout’s ground 
must be connected to each other, or connected to each other via a machine’s 
metal frame. A proper connection will eliminate ground loops that may cause 
unstable readings on the Readout. In 24VDC systems, proper ground 
connections will be improved by using only Readouts, Scales, & 
Encoders whose part #’s end in ‘G’. 
24VDC Digital Readouts are designed to run on DC voltage ONLY. 
DO NOT ATTEMPT TO OPERATE THESE READOUTS with AC VOLTAGE! 
24VDC 
Input
 / 
Output
Pin
Common
SPC Output
Encoder Input
SPC Output
Encoder Input
24VDC Input
Input / Output Pin 
C
ommon