Installation manual
Operation Manual for LCD Digital Readouts  Page 20 of 48 
Advanced Functions 
The following additional functions & operations are 
available on General Purpose Digital Readouts 
See PROGRAMMING PARAMETER (Pr23). 
ABSOLUTE VS INCREMENTAL MEASUREMENTS. 
The Digital Readout has two measurement “indexes”. One 
is  referred  to  as  ABS  and  the  other  is  INC.    The  ABS 
measurement setting is designed to allow the user to set 
an “absolute“ zero point on the Digital Readout referenced 
from  a  fixed  or  known  position.    The  INC  measurement 
setting  is  designed  to  take  relative  or  “incremental”  distance  measurements 
from  one  arbitrary  point  to  another.    The  settings  operate  independently 
allowing  separate  position  offsets  to  be  programmed  for  ABS  and  INC.  The 
Absolute  position  of  the  measuring  system  is  not  lost  when  using  the 
Incremental (INC) settings and will be recalled and displayed when the Readout 
is  returned  to  Absolute  (ABS)  mode.  The  terms  “Absolute”  and 
“Incremental”  are  used  here  to  describe  a  measurement  function  or 
technique  and  should  not be confused  with  the  terms  Absolute  and 
Incremental  when  used  in  reference  to  the  type  of  “Measuring 
Technology” employed by different ProScale products. 
ABS  
The Digital Readout automatically enters ABS (Absolute) mode when power is 
first applied.  This is indicated by the ABS
ABSABS
ABS symbol in the upper left corner of the 
LCD.  While  in  the ABS mode, all position measurements are  related to  the 
current system reference point. To enter the INC 
(Incremental)  mode,  press  &  hold  the ABS/INC 
key for 1.2 seconds. 
NOTE:  To change  the  timing  of this  key  to  a 
momentary  press  to  enter  INC  mode,  See 
Programming Parameter (Pr22). 
INC 
While in the INC (Incremental mode), the INC
INCINC
INC symbol is shown in the upper left 
corner  of  the LCD.    When the  INC  mode  is  initially  entered,  the  displayed 
position will change to reflect a new reference point at the current position of 
the Encoder.   This is typically  a position of  zero (0) but may be changed by 
using the + or – Key to enter an offset.  Moving the Encoder in either direction 
will display the distance moved from the initial Incremental starting point (plus 
any  offset).   To  complete  another incremental measurement  from the new 
position, momentarily  press  the  ABS/INC key.    The  Digital  Readout  will  again 
change to 0.00 (or the previously programmed offset).  To return to the ABS 
mode, press and hold the ABS/INC key for 3 seconds. 