Pr 26 – Position Monitor Drift Tolerance.  [.0004” to 120”, .01”] 
This parameter sets the amount of drift that must occur in MONitor mode to 
trigger a drift condition indication. 
Default = .01” 
Pr 27 – Use Soft Limits.         [0 or 1] 
Enables or disables the use of soft limits. If enabled, a message on the LCD is 
displayed when the measuring system is operating outside the programmed 
(Pr 28 & Pr 29) position limits. 0 = off, 1 = on. 
Default = 0 (off)   
Pr 28 – Lower Soft Limit Position.  Range: Any displayable position. 
Defines the position to be used as the lower limit if the Use Soft Limits 
parameter is enabled (Pr 27=1). 
Default = 0.000 
Pr 29 – Upper Soft Limit Position.  Range: Any displayable position 
Defines the position to be used as the upper limit if the Use Soft Limits 
parameter is enabled (Pr 27=1). 
Default = 5.000” 
Pr 30 – Offset Addition Enable.      [0 to 4, 0] 
Enables or disables offset addition function. This feature allows the user to 
choose from up to 4 programmed values that can be added to the current 
position using the F1 key. 
1 = Offset 1 enabled    2 = Offsets 1 & 2 enabled 
3 = Offsets 1, 2 & 3 enabled  4 = Offsets 1, 2, 3 & 4 enabled 
Default = 0 (Disabled) 
Pr 31 – Offset Addition Preset 1.  Range: Any displayable position 
This value is added to the current ABS position when Offset Addition is enabled 
(Pr 30 not set to 0) and Offset Preset 1 is selected with the F1 key. 
(1 
1 1 
1 segment displayed on LCD). 
Default = .5” (12.7mm) 
Pr 32 – Offset Addition Preset 2.  Range: Any displayable position 
This value is added to the current ABS position when Offset Addition is enabled 
(Pr 30 not set to 0) and Offset Preset 2 is selected with the F1 key. 
(2
22
2 segment displayed on LCD). 
Default = 2” (50.8mm) 