Installation manual
Operation Manual for LCD Digital Readouts  Page 8 of 48 
Digital Readout Specifications 
Linear Measurements: 
  Display Ranges:  + 999.999 in; + 399 63/64 in 
      + 9999.99 mm; + 999.999 cm 
Resolution:*    .1inch  .1mm  .1cm  or 
  .01inch  .01mm  .01cm  or 
    .001inch  .01mm  .001cm or 
    .0005inch .01mm  .001cm 
  Repeatability:    .001in or .01mm or .001cm 
Temperature Measurement: 
  Accuracy:  + 1º C from 0 to 70º C, + 2º C otherwise.  
  Resolution:    .1º C 
Operating Power:     
  Basic:    2 AA Batteries 
  General Purpose:  2 AA Batteries or 9-24VDC 
  Panel Mount:    1 CR123 3V Lithium Battery or 24VDC 
Operating Temperature:  32 to 120°F, 0 to 50°C 
Output:     
  Basic:    None 
  General Purpose:  Mitutoyo Digimatic® SPC 
  Panel Mount:    Mitutoyo Digimatic® SPC 
* Position data displayed on the LCD and sent to the SPC port is auto-ranging. 
This means that the defined resolution may be temporarily overridden by the 
system if the position to be displayed or sent exceeds the allowable maximum 
position for that resolution. In that case, the system will continue to reduce the 
resolution until either an allowable resolution is achieved or to 1 decimal place 
to the right of the decimal point. Maximum displayable values are: 
Inch Resolution  Maximum Value (Inches) 
4 decimal places  99.9999 
3 decimal places  999.999 
2 decimal places  9999.99 
1 decimal place  99999.9 
Millimeter Resolution  Maximum Value (mm) 
2 decimal places  9999.99 
1 decimal place  99999.9 
Table 1.1  Maximum Resolution 