1.  Note the orientation of the ReadHead on the Scale.  Be sure the arrow 
on the ReadHead points towards the “BLACK END OF SCALE”.  This 
orientation is critical for proper operation.  Be sure the mounting location 
for the ReadHead and Scale will allow this orientation. Take care when 
sliding the  ReadHead  onto the Scale so the brass “fingers” inside the 
ReadHead  do  not  get  damaged.  (A  slight  “wiggling”  motion  when 
installing the ReadHead will simplify the process.) 
2.  Determine an appropriate mounting  location.  Most applications of the 
Model 150  will  have  the  ReadHead  held  stationary  while  the  Scale  is 
passed through the ReadHead. The ProScale will also operate properly 
if the ReadHead is moved along the Scale (see figures on next page). 
3.  If the ReadHead is to be  mounted stationary, the 
Scale should be attached to a moving part of the 
measuring  application  or  machine  using  the 
Connector Link. Attach the ReadHead  using three 
screws or bolts.  Attach one end of the connector link 
to the Scale using the included 10-32 screw (or M5) 
and the other end to the moving part.  Check that the 
Scale is properly aligned with the direction of motion 
of  the  moving  part.    Be  sure  both  connections  are 
secure  or  inaccurate/erratic  readings  could  result. 
(The  connector  link  compensates  for  small 
misalignments of the installation and acts as a shear 
pin).  Failure to use the connector link could void the warranty. 
4.  If  your  application  is  more  suited  to  the  Scale  being 
held stationary and the ReadHead moving, you should 
use the Guide Clip to  move the ReadHead along the 
Scale (see figure on next page). The connector link is 
not  necessary in this configuration.  Mount the  Scale 
using the included 10-32 screw (or M5).  Be sure the 
Scale  is properly  aligned as the ReadHead  is  moved 
(the Guide Clip will compensate for slight misalignment 
in  one  direction  only).    Adjust  Scale  alignment  if 
necessary. 
For  accurate  measurements,  the  guide  clip  must  be  mounted 
perpendicular to the direction of travel of the ReadHead.  The guide clip 
should  exert  some  pressure  over  the  full  range  of  travel  on  the 
ReadHead so the two move as a single  unit. Failure  to use the guide 
clip could void the warranty. 