5.  The Display may be mounted in a location which allows for easy viewing 
by  the  operator.    The  location  of  all  parts  should  also  safeguard  the 
cable from possible damage.  ProScale wiring should be kept away from 
electrical wiring and motors.  Plug the ReadHead into the Display.  See 
Section 4: DISPLAY OPERATION. 
Note:  If any other mounting method is used, observe the following: 
•  Do not drill through the green portion of  the Scale at any point over 
which the ReadHead will travel. 
•  Do not mount the Scale so the mounting hardware interferes with the 
movement of the ReadHead. 
Typical Model 150 Installations 
G uide C lip 
Sc ale
R ea d h ea d
M ovin g pa rt 
Readhead stationary, Scale moves
Scale stationary, Readhead moves
Moving Part 
Connector Link 
Readhead
Scale