User`s manual
Accurate Technology ProScale  Page 30 of 48 
Pr8 – Automatic Power Off      [0 to 60] Default = 15 
Sets the amount of time in ‘minutes without activity’ before the 
Display automatically turns off. 
0 = Disables Automatic Power Off. 
ReadHead motion or ON/OFF key will “wake-up” the Display and 
reset the timer.   
Pr9 – Auxiliary Keys Enable/Disable    [0..7] 
0 = ABS/INC, MON and HOLD Disabled 
1 = ABS/INC Key Enabled 
2 = MON Key Enabled 
4 = HOLD Key Enabled 
7 = All Keys Enabled 
To enable keys, add up combination of key values. A value of 2 
enables only the MON key.  A value of 7 enables all 3 keys. 
Pr10 – Offset Addition Enable     [0, 1] 
0 = Offset Addition Disabled. 
1 = Offset Addition Enabled.  
SEE ALSO Pr11, Pr12, Pr13. 
Pr11 – Offset Addition 2 
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]    
        Default = 1.000 in. (25.40mm) 
When offset 2 is selected (see Section 4: OFFSET ADDITION), 
this value is added to the current ABS position.  
Only active if Pr10 is set to 1. Default is set in Inches. 
Pr12 – Offset Addition 3 
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]    
        Default= 1.500 in. (38.10mm) 
When offset 3 is selected (see Section 4: OFFSET ADDITION),  
this value is added to the current ABS position and displayed. 
Only active if Pr10 is set to 1. Default is set in Inches. 
Pr13 – Offset Addition 4 
[-999.999 to 999.999in] or [-9999.99 to 9999.99mm]    
        Default= 2.000 in. (50.80mm) 
When offset 4 is selected (see Section 4: OFFSET ADDITION), 
this value is added to the current ABS position and displayed. 
Only active if Pr10 is set to 1. Default is set in Inches. 