User`s manual
ProScale M150, M250 with LCD Digital Displays  Page 33 of 48 
Primary Key Functions 
ON/OFF 
Momentarily pressing the ON/OFF key will cause the Display to turn on or off. 
The Firmware Version is momentarily displayed on power-up.  While on, if no 
key presses or positional changes occur within 15 minutes*, the Display will 
automatically  turn  itself  off  to  conserve battery  life.    While  off,  if  a position 
change  is  detected  (larger  than  .05mm  or  .002in),  the  Display  will 
automatically turn itself on with no loss of measurement information. 
*(Programming Parameter Pr8) 
Pressing  and  holding the  ON/OFF  key  for  5 seconds  while  the  Display  is 
turned on will display internal battery voltage. 
MODE 
The  ProScale  can  display  measurement  information  in Inch  or  Metric.    To 
change the display mode, momentarily press the MODE key. With each key 
press, the Display will cycle through decimal inches, fractional inches* (1/16), 
(1/32),  (1/64) and metric (mm or  cm  based  on setting of Programming 
Parameter Pr5). * If enabled by Programming Parameter Pr6. 
When the Display is in a decimal  mode (mm, cm or in) it will auto-range to 
the next resolution if the value is displayable in the next range.  This allows 
the  Display to be  used  with  Mitutoyo  Digimatic®  products in  inch  mode  or 
different resolutions other than 2 decimal places. 
When the Display is in 1/16 or 1/32 inch fraction mode, a series of “bars” in 
the  upper  right  corner  of  the  LCD  each  represent  1/64th  of  an  inch 
measurement. (ie. When in 1/16 inch mode and three bars are showing, the 
measurement displayed  is rounded down  to  closest 1/16 inch and  each 
illuminated  bar  indicates  an  additional  1/64  of  an  inch  (“heavy”) 
measurement.)  For  better  resolution  switch  to  1/32  or 1/64 fraction  mode.  
For the best resolution switch to a decimal mode. 
When the measurement is greater than +  99 63/64 inches, a +100 or +200 
will show in the  upper right portion of the LCD to indicate this amount must 
be added to the displayed reading. ie: if the measurement is 154 5/8 inches, 
54 5/8 and +100 will be displayed on the LCD. If the measurement is -307 
23/64 inches, - 7 23/64 , +100 and +200 will be displayed on the LCD. 
The  Resolution  of  the  Display  can  be  set  for  NORMAL:  (.01mm  or  .001in), 
REDUCED: (.1mm or .01in) or INCREASED: (.01mm or .0005in).  
(Programming Parameter Pr4.) 