User`s manual
ProScale M150, M250 with LCD Digital Displays  Page 45 of 48 
SECTION 5  MISCELLANEOUS 
 Frequently Asked Questions 
What does āno Encā mean? 
If  the  ReadHead  is  off  the  Scale,  or  the  ReadHead  cable  is 
unplugged from the Display, a āno Encā will appear on the Display.  
To clear error: 
1.  Be sure the ReadHead is on the Scale and properly oriented. 
2.  Unplug the connector from the Display for one second. 
3.  Reconnect the ReadHead cable to the Display. 
The battery clips seem to be very loose.  Is this normal? 
YES!    DO NOT attempt to  bend these clips or  wedge  anything 
between  them  and  the  case.    These  clips  are designed to expand 
when the two case halves are screwed together. 
Can I mount the Scale/ReadHead without the connector link/guide clip? 
The connector  link and  guide clip serve  to provide  an  accurate 
method  of  transferring the  movement  of  the  moving part  to  the 
ReadHead or Scale, while  also  absorbing any stresses that may 
occur.  If they are not used, the warranty could be voided. 
The Display reads numbers but they seem to be random. 
1.  Be sure  the ReadHead is  oriented  correctly on  the  Scale.  One 
end  of the  Scale  is black;   be  sure that  the arrow  on  the 
ReadHead is pointed in this direction. 
2.  If using a Hi-Speed ReadHead, be sure Programming Parameter 
Pr2 is set to 1. 
The Display does not change, or changes very little, as the Scale or 
ReadHead moves. 
1.  The  Display  is  in  the  HOLD mode.  Press  &  release  the Hold 
button. 
2.  The ReadHead is on the Scale backwards. 
3.  The Scaling factor is set very low. 
4.  If using a Hi-Speed ReadHead, be sure Programming Parameter 
Pr2 is set to 1. 
Product Communication 
ProScale's  electrical interface  allows  the  ReadHead position  to  be  read 
directly or through the Display by a computer or other data acquisition device.  
Interface diagrams are available upon request. 