Manual

Appendix A FAQ
51
15. What should I do when I see below error message on LCD?
Ö Condition 1
R A I D F a i l
C o d e : 0
Note: not enough number of function disks for a RAID to operate
Solution: Install all of 4 disks to conform to create a new RAID.
Ö Condition 2
R A I D F a i l
C o d e : 1 < x x x x >
Note:
Represents disk sequence is wrong, and the current sequence displayed within <>
Solution: Replace the sequence of disk as original.
Example:
<2134>: disk 2 and disk 1 sequence is reversed.
<13x4>: the original disk 3 is put into tray 2 and the original disk 2 is not plugged
or failed.
Ö Condition 3
R A I D F a i l
C o d e : 2
Note: The RAID has been failed but all of 4 disks exist. Since F/W Version 1.4 or
later.
Solution: To create a new RAID or you should call Accusys product support center
to try to save the data from system.
格式化: 項目符號及編號
格式化: 項目符號及編號
格式化: 項目符號及編號
刪除: I loaded four disks
and turned on the
subsystem to set up an
array but the display
shows “RAID fail” and
the alarm is sounding.
How do I solve the
problem?