User Manual

Using the RAID GUI
2-60
3. Check the ‘Apply connection mode and data rate to all FC ports
option if necessary.
Check the ‘Apply data rate to all SCSI ports’ option if necessary (SCSI
port).
4. Click Apply and the ‘Restart to Apply’ prompt box appears. Click
Restart to restart the controller immediately, or OK to restart later.
5. All settings except FC/SAS/SCSI port name are effective after you
reconnect the controller.
Setting FC Worldwide Node Name
The default worldwide port name (WWPN) of each FC port should be
different. The assignment of worldwide node names (WWNN) to all FC
ports help the RAID system recognize all the FC ports with the same
WWPN as one device.
To set FC worldwide node name, click the WWNN button. Then select
Distinct to use different FC WWPNs, or Identical to synchronize all FC ports
using the same WWNN. Click Apply to save. The WWPN of all FC ports will
be synchronized the next time you start the RAID system.
Connection
Mode
Auto: The controller will determine the connection
mode automatically.
Arbitration loop: This is a link that connects all the
storages with the host, which enables data
transferring.
Fabric: This is a point to point connection mode
without a switch.
Default SCSI ID (For SCSI port)
Select a fixed SCSI ID for each SCSI port from the
drop-down menu. The ID range is from 0 to 15.
Data Rate Auto / 1GB / 2GB / 4GB
Select a preferred data rate for an FC port or all
FC ports.
(For SCSI port)
Async / Fast / Fastwide / Ultra / Ultrawide / Ultra2 /
Ultra2wide / Ultra3 / Ultra320
Select a preferred data rate for an SCSI port or all
SCSI ports.The default setting is Ultra320.