User Manual

Appendix
D-6
Roaming
Recovery
Event ID
0x2063
Type
RAID
Severity
NOTICE
Parameters
Rebuild
progress,
DG ID,
Notify
threshold
Message
Rebuild progress(y%) on DGx reach to the notify percent(z%)
Description
The progress of rebuilding has reached the pre-define threshold.
Advice
None
Event ID
0x0820
Type
RAID
Severity
INFO
Parameters
Message
Disks changed during power-off
Description
The number of disks installed is different when the controller was
powered off. Either existing disks were removed or new disks were
installed during power-off.
Advice
Check hard disk status, and conduct roaming or recovery, if nec-
essary.
Event ID
0x1004
Type
RAID
Severity
INFO
Parameters
DG ID
Message
DGx is imported
Description
Foreign disk group has been imported to be dgx.
Advice
None
Event ID
0x1c02
Type
RAID
Severity
INFO
Parameters
VOL ID
Message
VOLx is imported
Description
Foreign volume has been imported to be volx.
Advice
None
Event ID
0x2052
Type
RAID
Severity
INFO
Parameters
DG ID
Message
DGx is recovered
Description
Disk group dgx has been recovered.
Advice
None