User Manual

Appendix
D-18
Event ID
0x204a
Type
TASK
Severity
WARNING
Parameters
DISK ID
Message
Scrub on HDDx failed to start by schedule
Description
Scheduled disk scrubbing on hddx failed to start.
Advice
Check if the disk is off-line or busy.
Event ID
0x2020
Type
TASK
Severity
INFO
Parameters
DISK ID,
Sector Num
Message
Scrub on HDDx stopped with y bad sectors detected
Description
Disk scrubbing on hddx was stopped manually, and y bad sec-
tors were detected.
Advice
If the number of bad sectors grows exceptionally fast or beyond
a reasonable number, consider to conduct diagnostics and
replace with new disks.
Event ID
0x2055
Type
TASK
Severity
WARNING
Parameters
DISK ID,
Sector Num
Message
Scrub on HDDx aborted with y bad sectors detected
Description
Disk scrubbing on hddx was aborted, and y bad sectors were
Advice
Check if the disk is off-line or busy.
Event ID
0x2038
Type
TASK
Severity
NOTICE
Parameters
DISK ID,
Sector Num
Message
Scrub on HDDx completed with y bad sectors detected
Description
Disk scrubbing on hddx was completed, and y bad sectors were
Advice
If the number of bad sectors grows exceptionally fast or beyond
a reasonable number, consider conducting diagnostics and
replace with new disks.