User Manual

Appendix
D-36
Disk Cache
Event ID
0x1405
Type
DISK
Severity
WARNING
Parameters
Disk ID
Message
Primary BBR table on HDDx is corrupt
Description
The controller failed to access the primary BBR table on hddx
and the table was invalid. However, the secondary BBR table still
works.
Advice
Start to monitor the status of the secondary BBR table on this disk.
Event ID
0x1406
Type
DISK
Severity
WARNING
Parameters
Disk ID
Message
Secondary BBR table on HDDx is corrupt
Description
The controller failed to access the secondary BBR table on hddx
and the table was non-trustable. However, the primary BBR table
still works.
Advice
Start to monitor more carefully the status of the primary BBR table
on this disk.
Event ID
0x1407
Type
DISK
Severity
WARNING
Parameters
Disk ID
Message
Both BBR tables on HDDx are corrupt
Description
The controller failed to access both primary and secondary BBR
tables on hddx, and the tables were non-trustable. In this case,
the BBR functions cannot work any more.
Advice
Replace with new disks to prevent from data loss.
Event ID
0x082a
Type
DISK
Severity
INFO
Parameters
Disk ID
Message
HDDx cache is enabled
Description
Disk cache of hddx was enabled by user.
Advice
None
Event ID
0x082b
Type
DISK
Severity
INFO
Parameters
Disk ID
Message
HDDx cache is disabled
Description
Disk cache of hddx was enabled by user.
Advice
None