User Manual

Appendix
D-40
Event ID
0x3009
Type
HOST
Severity
WARNING
Parameters
Chip ID,
Controller ID
Message
Reset host i/f chip x in controller y
Description
The controller resets chip x that failed to execute commands
properly. This could be to recover from a transient error due to
unstable channel or heavy traffic. The controller will resume nor-
mal operations of the chip after reset; however, this could result
in performance drop of the LUNs exported to the host ports of this
chip.
Advice
If this event occurs often, check the host connectivity, or contact
local sales or support office.
Event ID
0x300a
Type
HOST
Severity
FATAL
Parameters
Chip ID,
Controller ID
Message
Host i/f chip x in controller y failed
Description
The controller cannot execute commands properly on chip x
after all appropriate recovery procedures were conducted. This
could be resulted from unstable power supply to the system. All
LUNs controlled by the chip will be unavailable to hosts.
Advice
Check power supply, replace with a new controller, or contact
local sales or support office.
Event ID
0x300b
Type
HOST
Severity
ERROR
Parameters
Host Chan-
nel ID, Con-
troller ID,
Error Code
Message
Host channel x in controller y PCI Error: z
Description
The controller has detected error in the host channel.
Advice
Check if the power supply is stable. Contact local sales or sup-
port office.