User Manual

Appendix
D-46
Event ID
0x301e
Type
HOST
Severity
WARNING
Parameters
Host Port ID
Message
Host port x too much write data
Description
More than the expected amount of write data was received
from the initiator.
Advice
None
Event ID
0x301f
Type
HOST
Severity
WARNING
Parameters
Host Port ID
Message
Host port x IU too short
Description
A received information unit was shorter than the value allowed
by the protocol specification.
Advice
None
Event ID
0x3020
Type
HOST
Severity
WARNING
Parameters
Host Port ID
Message
Host port x EEDP Guard Error
Description
The data in an end-to-end data protection I/O failed the CRC
guard check.
Advice
None
Event ID
0x3021
Type
HOST
Severity
WARNING
Parameters
Host Port ID
Message
Host port x EEDP Reference Tag Error
Description
The logical block reference tag in the data protection informa-
tion block of an end-to-end data protection I/O did not match
the expected value.
Advice
None
Event ID
0x3022
Type
HOST
Severity
WARNING
Parameters
Host Port ID
Message
Host port x EEDP Application Tag Error
Description
The logical block application tag in the data protection informa-
tion block of an end-to-end data protection I/O did not match
the expected value.
Advice
None