User Manual

Appendix
D-52
D.6 Enclosure
Temperature
Event ID
0x2800
Type
ENCLOSURE
Severity
NOTICE
Parameters
Sensor ID,
Enclosure ID,
Tempera-
ture
Message
Temperature at sensor x in enclosure y back to normal (z c)
Temperature at sensor x in controller back to normal (z c)
Description
The temperature at sensor x in enclosure y or controller returned
to normal working temperature range, right now is z ºC.
Advice
If the temperature is very unstable, contact local sales or support
office.
Event ID
0x2801
Type
ENCLOSURE
Severity
WARNING
Parameters
Sensor ID,
Enclosure ID,
Tempera-
ture
Message
Abnormal temperature detected by sensor x in enclosure y (z c)
Abnormal temperature detected by sensor x in controller (z c)
Description
The temperature at sensor x in enclosure y or controller has been
out of normal working temperature range, right now is z ºC.
Advice
Check the fans in the system and the air conditioning of the envi-
ronment.
Event ID
0x2802
Type
ENCLOSURE
Severity
ERROR
Parameters
Sensor ID,
Enclosure ID
Message
The temperature sensor x in enclosure y failed
The temperature sensor x in controller failed
Description
The controller cannot detect the temperature sensor x in enclo-
sure y or controller.
Advice
Contact local sales or support office.