User Manual

Appendix
D-61
Event ID
0x2401
Type
SYSTEM
Severity
INFO
Parameters
Message
RAID configurations on all disks erased
Description
RAID configurations stored on all disks were erased. All RAID con-
figurations are lost.
Advice
Restart the controller so that all disks can be re-initialized all
together.
Event ID
0x2415
Type
SYSTEM
Severity
INFO
Parameters
Message
NVRAM configurations restore to default
Description
The controller configurations stored on NVRAM were erased and
restored to factory default.
Advice
None
Event ID
0x2416
Type
SYSTEM
Severity
INFO
Parameters
DISK ID
Message
NVRAM configurations restored from HDDx
Description
The NVRAM configurations were restored from hddx.
Advice
None
Event ID
0x2417
Type
SYSTEM
Severity
INFO
Parameters
Message
NVRAM configurations restored from file
Description
The configurations were restored from a file uploaded to the
controller.
Advice
None
Event ID
0x2409
Type
SYSTEM
Severity
FATAL
Parameters
Message
NVRAM configuration checksum error
Description
The checksum stored on NVRAM do not match the contents on
NVRAM. This could happen if the controller was not properly shut-
down. Because NVRAM configurations might be corrupt and
cannot be trusted, all event logs are automatically erased.
Advice
Restore the configurations from hard disks or by uploading the
backed-up configuration file. If this event happens continuously,
contact local sales or support office.