User Manual

Appendix
D-67
Email (SMTP) server status
System start-up and shutdown
Event ID
0x2450
Type
SYSTEM
Severity
WARNING
Parameters
Message
Firmware version are not the same
Description
Firmware version are not the same, only one controller will be
startup
Advice
Check firmware version of both controller, and update the
wanted firmware to another controller
Event ID
0x240b
Type
SYSTEM
Severity
WARNING
Parameters
Message
Controller x failed to send mail
Description
The controller failed to send mail. Both primary and secondary
mail servers cannot be reached by the controller.
Advice
Check if the network connection is up, and check if the network
and SMTP settings are correct.
Event ID
0x240a
Type
SYSTEM
Severity
INFO
Parameters
Message
Controller x sned mail back to normal
Description
The controller can reach the mail server and start to send mail.
Advice
None
Event ID
0x2402
Type
SYSTEM
Severity
INFO
Parameters
Message
System to be restarted or halted
Description
The RAID system is going to get restarted or halted.
Advice
None
Event ID
0x2403
Type
SYSTEM
Severity
INFO
Parameters
Message
RAID system started
Description
The RAID system was started.
Advice
None