User Manual

Appendix
D-69
Fail-back
Event ID
0x2451
Type
SYSTEM
Severity
WARNING
Parameters
Message
Enclosure serial number are not the same
Description
Enclosure serial number are not the same, only one controller will
be startup
Advice
Check Enclosure serial number of both controller, and update
the wanted serial number to another controller
Event ID
0x2829
Type
SYSTEM
Severity
WARNING
Parameters
Message
BBM optional are not the same
Description
BBM optional are not the same, only one controller will be startup
Advice
Check BBM option of both controller, and apply the wanted
option to another controller
Event ID
0x2435
Type
SYSTEM
Severity
INFO
Parameters
Controller
ID, Control-
ler ID
Message
Boot code in controller x updated by controller y
Description
During fail-back, if the boot cade version of returning controller x
is not the same as controller y. The boot code of controller x will
be updated by controller y automatically.
Advice
None
Event ID
0x2436
Type
SYSTEM
Severity
INFO
Parameters
Controller
ID, Control-
ler ID
Message
System firmware in controller x updated by controller y
Description
During fail-back, if the system firmware version of returning con-
troller x is not the same as controller y. The system firmware of
controller x will be update by controller y automatically
Advice
None