Event ID
0x2438
Type
SYSTEM
Severity
INFO
Parameters
Message
Enclosure serial number in controller x updated by controller y
Description
During fail-back, if enclosure serial number of returning controller
x is not the same as controller y. The enclosure serial number of
controller x will be updated by controller y automatically
Advice
None
Event ID
0x2439
Type
SYSTEM
Severity
ERROR
Parameters
Message
RCC link or protocol not correct
Description
The internal link or transfer protocol of the returning controller
doesn’t work well
Advice
Contact local sales or support office
Event ID
0x243a
Type
SYSTEM
Severity
WARNING
Parameters
Message
The model name of the returning controller is not the same
Description
The model name of the returning controller is not the same
Advice
Make sure the model name of the returning controller is the
same. If not the same, replace the returning controller board.
Event ID
0x243b
Type
SYSTEM
Severity
WARNING
Parameters
Message
The Daughter board model of the returning controller is not the
same
Description
The Daughter board model of the returning controller is not the
same
Advice
Make sure the daughter board moduel of the returning controller
is the same. If not the same, replace the daughter boadr module
of the returning controller to make the models are the same.
Event ID
0x243c
Type
CONTROLLER
Severity
WARNING
Parameters
Message
The Memory size of the returning controller is not the same
Description
The Memory size of the returning controller is not the same
Advice
Make sure the memory size of the returning controller is the same.
If not the same, replace the memory module of the returning