Compact Solution Quick Start Guide Includes setup information for : Hardware set up: PCIe Switch SW04/08-G2, PCIe RAID System A08S-PS, QSFP cables and HBAs, Also incloud software setup information for: Exsan Setup, Xsan setup.
ExaSAN Compact Solution Quick Start Guide TABLE OF CONTENTS Page# Hardware Installation.......................................................................................................................................1 Checking the Equipment You’ll Need.............................................................................................3 Understanding the Installation Steps.................................................................................................
1 Hardware Installation Quick Start Guide P1
1.Hardware Installation Congratulations on your purchase of the “Accusys ExaSAN Compac Solutiont” SAN (Storage Area Network) system solution. This Quick Start Guide gives the step-by-step setup instructions of one sample basic system configuration. Our sample configuration consists of one RAID 8-bay disk system, one SW04 switch, and two Mac Pro host systems running Mac OS X Server. Figure 1 below depicts our sample ExaSAN Compact solution architecture. FIGURE 1.
1.1 Checking the Equipment You’ll Need The list below consists of all the equipment you’ll need to set up the ExaSAN Compact Solution. Note that while items 1 through 7 are Accusys-supplied equipment, they are not necessarily part of the ExaSAN switch package. Refer to Packing List for a complete list of accessories which are included in your SW04 package.
Package Item Image Item description PCIe 4 or 8-port switch, supports up to 4 or 8 host systems and 3 PCIe 1.
3 QSFP HBA 20Gb QSFP PCIe x4 Host Bus Adapter, supports PCIe 2.0 slot 10Gb PCIe 1.1 8-bay tower RAID system, supports SATA and SAS drives 4 A08S-PS package Power cord for A08S-PS RAID system 1.
. Ethernet switch and CAT-5 patch cables for the private Ethernet network of your SAN, one switch and one cable for each host system 9. SAN management software (Xsan 2.0 and MetaSAN is recommended,also Xsan is included in MacOS 10.7). 10.Eight SAS (Serial Attached SCSI) or SATA (Serial Advanced Technology Attachment) HDD’s for the A08S-PS RAID disk system (note that Enterprise HDD is recommended) 11.Two computers running Mac OS X Server operating system 1.
given, use the fastest PCIe slot available. Although the HBA is compatible with both PCIe 1.1 and 2.0 standards, only the latter is recommended for best performance. Follow these steps to install the card in each host system: 1. Hold the HBA with mounting plate facing your left. Locate the “mode” jumper switch on the north edge at center-right, as shown and labeled below. 2. Re-position the HBA so that you are facing the three switch buttons.
3. Position the connector of the card over the slot, insert the connector into the slot, press gently but firmly until it is securely seated. 4. Secure the metal bracket of the card to the system case with a screw. 5. Replace the outer casing cover. 6. Install HBA device driver a. Insert the Installation CD b. Launch the Installation Package (for Mac) c. Follow the on-screen instructions to complete the driver installation 1.3.2 Connecting Switch to the RAID Disk System 1.
2. Insert the other end of the cable into one of the three storage module ports on the rear panel of the ExaSAN switch. 3. Plug a power cord into the AC power-in port in the storage unit; do not turn power on yet. 1.3.3 Connecting Switch to the Host System 1. Connect your workgroup host system #1 to the ExaSAN switch with a QSFP cable. Insert one end of the QSFP cable into one of the host module ports on the rear panel of the switch. Your cable connector is securely plugged when you hear a click.
1.3.4 Connecting the Private LAN In addition to the ExaSAN PCIe network, all computers for the SAN must be connected to a private Ethernet network (the Private LAN). Xsan MDC servers and clients use this network instead of the ExaSAN network to exchange file system metadata. Connect each SAN client and MDC servers to two Ethernet networks: one private subnet for the SAN metadata and a separate connection for directory service, intranet, and Internet traffic (the Public LAN).
3. Turn power on for the ExaSAN switch by pressing the Power button. Wait for the Heartbeat LED to turn into a steady flashing blue state. Note that you might hear a few short beeps generated from the switch during this process. You may ignore them as they are designed for Accusys’ internal diagnostic purpose only. No. Name 1 Cooling Vents 2 Power LED Indicator 3 Access LED Indicator 4 Fan LED Indicator 5 Heartbeat LED Indicator 4. Turn your primary MDC on first and wait for it to become ready.
P12 Quick Start Guide
2 Software Installation and Configuration Quick Start Guide P13
2. Software Installation and Configuration Now that we have connected all hardware components and turned on the power, follow the steps in this section to set up ExaSAN and Xsan. 2.3 ExaSAN Setup 2.3.1 Switch GUI Setup The ExaSAN switch has a browser-based built-in GUI (Graphical User Interface) for administration and configuration tasks. 2.1.1.1 Launch the Switch GUI You may use either the FireFox or Safari browser to access the switch GUI. We recommend that you use FireFox. 1.
2.1.1.2 Switch GUI Overview We are now at the switch GUI main menu page. You may toggle between “Config Mode” and “Monitor Mode” by clicking the “Switch Mode” icon at the top. You may also go into “System Management” to change the switch IP and password, or to set system date and time.
Note that before you perform any system administration function, you should set your system date and time first. 2.1.1.3 Quick Setup We will create two LUNs in the RAID disk system. One is for the Xsan metadata and the other for the user data. 1.
2. In the “RAID LEVEL” field, select “R5” from the drop-down list 3. In the “SAN Software” filed, select “SAN With MetaData” from the drop-down list 4. Click “Next” *Quick Setup only supports one-to-three unit A08S-PS, if your RAID system requirement is other form factor like 2U/3U/4U, you may have to reset the setting through RAID Guide X. Please refer to the User Guide for the RAID configuration information.
As the result, two logical disks will be created as shown in the screenshot below. 5. Click “Apply” After you click the “Apply” button, the system will start the process of initializing the disks in your RAID storage system. During this process, you may experience deterioration in overall system performance, this is normal. Please allow sufficient time and patience for this process. Upon completion, the LED indicators on the front panel of your RAID system will reflect that status.
2.1.2 Verify Accessible LUNs To view the two LUNs which we just created, open the Mac “System Profiler” and then expand the “Parallel SCSI” tab. You should see that two ExaSAN LUNs are visible as described below. Find one LUN in “SCSI target Device @0,” another LUN in “SCSI Target Device @1.” Both are identified with Manufacturer “ACCUSYS” and Model “A08SPS.” Note that you will need to perform this check on all computers in the SAN.
2.2 Xsan Setup Now that we’ve completed the ExaSAN configuration, this section guides you through the setup of your Xsan software: including how to check the accessible LUNs and use the Xsan Admin application, plus create and mount an Xsan volume. 2.2.1 Setup Xsan with MDC (Metadata Controller) and Clients First we will install the Xsan software and then create a SAN (Storage Area Network) without LUNs. 2.2.1.
Next, repeat the same Xsan software installation on the backup MDC. 2.2.1.2 Configure the SAN with MDC and All Clients Step by Step Next we will proceed with configuring Xsan. Choose one of your two computers as the designated primary MDC. Click the Xsan Admin icon to start configuring your SAN. Below are screenshots of this process to assist with your understanding.
Click “Continue.” Select “Configure new SAN,” click “Continue.
Fill in the “SAN Name” of your choice; also fill in the appropriate “Administrator Name” and “Administrator Email” address. Click “Continue.” Select the computer(s) to add by putting a check mark on the left for each, click “Continue.” NOTE: you need to add at least one computer into the SAN as a metadata controller. Also see Section 2.2.1.3 “Adding More Computers into the SAN” about adding more computers at a later time.
Use same authentication information for all SAN computers: Select this option to allow Xsan Admin to authenticate all computers using the same administrator name and password you as entered here. Authenticate to SAN computers one by one: Select this option to authenticate each computer individually. Click “Add Serial Number” to enter serial number for each computer. Note that the Xsan file system is built into Mac OS X (Lion).
When you’re done adding Serial Numbers, click “Continue.” Select the appropriate private network IP address from the drop-down list, click “Continue.
You will not be able to go back for corrections beyond this point. Make sure that the information in the summary is correct, click “Continue.” Select the “Create one or more volumes later” option, click “Continue.” Note: we will create an Xsan volume later.
Click “Continue.” Upon completion of Setup, you are presented with the SAN overview as shown below.
2.2.1.3 Add More Computers into the SAN You can add more computers into the SAN by clicking the “Add (+)” button in the “Computers” pane. 2.2.2 Adding the ExaSAN RAID System into the SAN Now we will check accessible LUNs and then create an Xsan volume. 2.2.2.1 Labeling LUNs Before we label the two LUNs, first verify that they are listed in the “Parallel SCSI” pane under “Hardware.” Launch Xsan Admin and then click the “LUNs” tab to check if the two LUNs are also there.
Enter the LUN label name “Meta-LUN” for it in the subsequent dialogue box; click the “Label” button to confirm the entry.
Next, do the same for the 1.45TB LUN (the larger of the two LUNs) using the label name “Data-LUN.” Upon completion, you will have successfully labeled both LUNs as shown below.
2.2.2.2 Creating an Xsan Volume In Xsan Admin, click “Volumes” and then click the “Add “ (+) button to start creating an Xsan volume. Fill in the “Volume Name” of your choice; we will use the name “Demo” in our example. Select the appropriate “Volume Type” from the drop-down list. Click “Continue.” NOTE: select “Custom” in Volume Type for now. You can fine-tune the volume settings later.
Follow the on-screen instructions, click “Continue,” the result follows, click “Continue” again.
Click “Continue,” wait for volume creation to complete.
Upon completion of volume creation, they appear in the “Volume” tab as shown below. 2.2.2.3 Mounting or Un-mounting a Volume In Xsan Admin, click the “Mounts” tab to check if the volume was mounted or not. Select and right click a volume if you want to mount or un-mount it. At this point, you have created an Xsan volume and mounted it. All host systems may now access it as if it was a local disk.
3 Technical Support Quick Start Guide P35
3. Technical Support 3.1 The System Log When you contact us for technical support, our support staff might ask for your system log file for troubleshooting purpose. Go to the ExaSAN switch GUI, select the “Event Management” icon. Follow instructions there to download the log file. 3.2 Contact Us For customer services and technical support, locate an Accusys office near you from the link below: http://www.accusys.com.tw/about/contact.htm or, you may e-mail us at: support@accusys.com.tw 3.
Quick Start Guide P37