User guide

August 2001 179
Switching Calls through the MVIP-90 Bus
After the caller enters an extension, the application determines
which line that extension uses and makes the appropriate
connection. In this example, the requested extension uses the
fourth resource on the RTNI-ATSI.
The T1 board breaks the connection with the Vantage VRS and
makes a connection with stream 5 on the MVIP bus. The
RTNI-ATSI board also makes a full-duplex connection with
stream 5. The RTNI-ATSI board then rings the extension
selected by the caller.
Figure 37. The T1 Transfers the Call to the Appropriate
Extension
Trunk 0
RTNI-2TI
RTNI ATSI
Vantage VRS
(16, 3)
(16, 3)
(16, 0)
(16, 0)
VP
DSi5
DSo5
DSi6
DSo6
Stream 16
Stream 16