Product Manual

4. With your free hand placed under the 7. Disconnect the large air supply hose
control unit (so as to not let it drop), (top of control unit) by loosening hose
completely unscrew the union, clamp (slide clamp up onto hose).
allowing the control unit to separate
from the pressure vessel (place a small
container under the pressure vessel to
catch any remaining soda).
8. Disconnect the large blast nozzle feed
hose (bottom of control unit) by
loosening hose clamp (slide clamp up
onto hose).
5. Tip the control unit upside down, to
empty any soda that may still be in the
inlet fitting. With a pair of needle nose
pliers, remove the factory installed
1/8” restrictor and place it in a safe
place.
9. Place the control unit on a clean and
stable work surface, and remove the
four (4) Allen head machine screws
from the cover. Remove cover.
6. Disconnect the 1/8” air feed tube from
the control unit air cylinder. Place a
small piece of tape over the ends so
as not to get dirt or debris into tube or
cylinder
10. With a socket wrench, 2” extension
and 9/16”socket, carefully loosen the
two (2) controller adjustment bolts
(back of control unit above and below
the air cylinder), until both bolts are
completely loose. Set
18