Product Manual

weld nuts but from the flat top 21. Attach control unit to the bottom of
surface of the spring plate. This is the the pressure vessel. MAKE SURE
standard factory setting). THAT THE UNION THREADS ARE
FREE OF SODA AND SEATED
COMPLETELY.
19. Replace control unit cover with the (4)
hex bolts (washers against bolt
heads).
22. Reconnect all air feed and blast
hoses to the proper fittings. Tighten
clamps.
WARNING: NEVER OPERATE OR
ADJUST THE CONTROL UNIT WITH THE
CONTROL UNIT COVER OFF. CONTROL
TUBES ARE UNDER PRESSURE AND
THE CONTROLLER SPRING IS UNDER
GREAT COMPRESSION. EXPOSED
MOVING COMPONENTS PRESENT A
PINCH HAZARD.
20. Place the desired sized restrictor into
the control inlet.
21