3. Rebuild the Kernel:
/etc/conf/bin/idbuild -B
4. Reboot the system:
shutdown -i0 -g0 -y
Changing the Controller Configuration
If there is a need to change the IRQ of the controller at any time, refer to the
UnixWare manual under DCU. If a Mylex Disk Array Controller is the
primary controller, and a second, third or fourth Mylex Disk Array
Controller is to be added, set the interrupt for the secondary controller, then
power-cycle the system (power off, then power on).
When the system restarts, UnixWare identifies the controller and displays
the message New hardware instance mapped to static driver... The
controller should be detected automatically during the start up sequence.
Use DCU to verify the interrupts after logging-on the system.