Technical information

Chapter 1 23
Hardware Monitor Function
Environment Requirements
Drop Test
Item Description
Feature Smart fan control system, Thermal Cruise and Speed Cruise support
Six VID input pins for CPU Vcore identification
Two thermal inputs from optionally remote thermistors or 2N3904
transistors or Pentium 4 thermal diode output
Four external voltage detect inputs
Three intrinsic voltage monitoring (typical for Vbat, +5VSB, +5CC)
Two fan speed monitoring inputs
Two fan speed control (DC analog output)
WATCHDOG comparison of all monitored items
Overheat indication output
Issue SMI#, IRQ, OVT# to activate system protection
Item Specification
Temperature
Operating
+5
O
C ~ +35
O
C
Non-operating
-20
O
C ~ +60
O
C (storage packed), -10
O
C ~ +60
O
C (unpacked)
Humidity
Operating 15% to 80% RH, non-condensing
Non-operating
10% to 90% RH, non-condensing at 40
o
C
Vibration
Operating 5 ~ 500Hz, 2.20g RMS random, 10 minutes per axis in all three axes
Non-operating 5 ~ 500Hz, 1.09g RMS random, one hour per axis in all three axes
Drop Test
Definition The protection ability of packing & cushion must be capable of
withstanding, with no physical or functional damage, mechanical impact
from height-specific drops.
Test Standard
Package Cross Weight Drop Height Not of Drop
KGs lbs CM Inch
0~9.1 0~20 76 30 10
9.1~18.2 20~40 61 24 10
18.2~27.3 40~60 46 18 10
27.3~45.4 60~100 31 12 10
10 drops: one corner, three edges, six surfaces