Acer AT150 F1 Specifications
Technical Specifications
ns
(with bezel)
434 (W) x 648 (D) x 178 (H) mm (17.2 x 25.5 x 7 inches)
Form factor
4U tower, rack mountable
System inlet
temperature
Operating 10° - 35° C (50° - 95° F) at sea level wi th an
altitude derating of 1° C per 305 m (1.8° F per
1000 ft.) above sea level to a maximum of 3050 m
(10,000 ft.) no direct sustained sunlight. Maximum
rate of change is 10°C/hr. (18°F/hr.). The upper
limit depends on the type and number of options
installed. System performance may be reduced if
operating with a fan fault or above 30°C (86°F).
Non-operating -40° - 70° C (-40° - 158° F) Maximum rate of
change is 20°C/hr. (36°F/hr.).
Relative humidity
(non-condensing)
Operating 8 - 90 % relative humidity (Rh), 28° C (8 2.4° F)
maximum wet bulb temperature, non-condensing
Non-operating 5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing