Installation Guide

PRODUCT COVERED
DIMMING
Compatible with Cync 3-wire smart switch. Do not compatible with
regular dimmer. Download Cync App for dimming and other controls.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING
Risk of fire or electric shock. Installation requires knowledge of
luminaire
electrical systems. If not qualified, do not attempt installation.
Contact a
qualified electrician.
To prevent wiring damage or abrasion, do not expose wiring to edges of
sheet metal or other sharp objects.
This device is not intended for use with emergency exits.
These products are intended to be used in dry, damp or wet locations.
IC rated for direct contact with insulation.
PREPARE ELECTRICAL WIRING
Electrical Requirements
The LED fixture must be supplied with 120VAC 60Hz.
Grounding Instructions
The grounding and bonding of the overall system shall be done
in accordance with National Electric Code(NEC) Article 600 and local
codes.
Model Input voltage
(Vac, Hz)
Current
(mA)
Wattage
(W)
CFIXCNLR4S1
120, 60 110 13
CFIXCNLR6S1
120, 60 130 16
CFIXCNLR4C1
120, 60 110 13
CFIXCNLR6C1
120, 60 130 16
Note:
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:(1) This device may not cause harmful interference; (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Risk of Damage:
Must use UL approved conduit fittings for all enclosure box
connections to prevent wire cuts by sharp edges and excessive strain on wiring.