To confirm the latest progress rate, refresh the display by clicking Refresh.
3. Normal displays in the Status box. (When the formatting is in execution, the progress
status displays.)
If formatting is terminated abnormally, review the results.
The formatted logical information is updated and the window displays.
Table 7.2 Formatting Message
Displayed Action to be Taken
02-xxxx, 03-xxxx, 04-xxxx or 0B-xxxx For the above code, a hardware fault is assumed. If the fault is not recovered
after re-execution, contact Acer | HDS.
05-xxxx For the above code, an operation error is assumed. Upon checking the
following items and re-execute processing. If the error is not recovered,
contact Acer | HDS.
05-2500 or 05-2581 Is logical unit 0 defined?
05-2600 In spite of none of drive mounted states, is ALL RAID specified and is a
logical unit specified for ALL CAPA formatted?
05-2580 Is an attempt made to define a logical unit exceeding the capacity of the
defined RAID group?
0B-FD01 Switching a controller in charge of a logical unit occurred during formatting.
Check the controller in charge and re-execute formatting from the controller
in charge.
DMEA000006 or DMEA000007 Drive failure recovery or ShadowImage-In-System Replication, TrueCopy
Synchronous Remote Replication, and/or Copy-on-Write Snapshot may be in