Technical data

Acer | HDS AMS200 User and Reference Guide 33
Table 2.10 Input Power and Insulation Performance Specifications for the Floor Model
Floor Model Item
Model
Floor (RKS+H1J) Model Floor (RKS+RKAJ+H2J) Model
Input voltage (V) AC 100/200 (100-120/200-240)
Frequency (Hz) 50/60 ± 1
Number of phases,
cabling
Single-phase with protective grounding
Steady-state current (A)
(Note 1) (Note 2)
4.0×2/2.0×2 4.0×2+2.6×2/2.0×2+1.3×2
Breaking current (A) 16.0
Steady state
(VA)
800 or less 1,320 or less
Required
power
Starting
state (VA)
800 or less 1,360 or less
Input power
specification
Heat value (kJ/h) 2,880 or less 4,755 or less
Insulation
Insulation withstand
voltage
AC 1,500 V (10 mA, 1 min)
performance Insulation resistance DC 500 V, 10 M Ω or more
Note1: Power current of Nx2 described above is required for operation by a single power supply unit.
Note2: The current value in the operation by a single power supply unit is same as that in the operation by both power
supply units.
Table 2.11 Input Power and Insulation Performance Specifications for the NAS Unit
Item Model
RKNAS
Input power Input voltage (V) AC 100/200 (100-120/200-240)
specification Frequency (Hz) 50/60 ± 1
Number of phases, cabling
Single-phase with protective grounding
Steady-state current (A) 2.0/1.4
Breaking current (A) 10.0
Required
power
Steady state
(VA)
280 or less
Starting state
(VA)
280 or less
Heat value (kJ/h) 1,010 or less
Insulation
performance
Insulation withstand
voltage
AC 1,500 V (10 mA, 1 min)
Insulation resistance DC 500 V, 10 M Ω or more