Quick Reference Guide
Table Of Contents
- 009-1950-02 Savant Product Information and Regulatory Statement-1 - 副本
- 009-2245-00 Smart Energy Monitor Module [GPM-H2SEM] - Quick Reference and Installation Guide
- 009-2240-00 Smart Energy Monitor Module [GPM-Q2SEM] - Quick Reference and Installation Guide
- 009-2241-00 Smart Energy Monitor Module [GPM-C2SEM] - Quick Reference and Installation Guide
Smart Energy Monitor - QRG | 009-2245-00 1 of 4 45 Perseverance Way, Hyannis MA 02601
Copyright ©2022 Savant Systems, Inc | 220930 Savant.com | 508.683.2500
DO NOT
PRESS ON
SCREEN
REMOVE AFTER
INSTALLATION
PAIR
B
A
C
E
D
GPM-H2SEM
MODULE INPUT: 120VAC 60Hz
SERIAL INPUT: 0.333vac 60Hz
#18-24 AWG Min. 105°C Cu Only
IC 10798A-HQCSEM
FCC ID PUU-HQCSEM
INDOOR USE ONLY
CT CONNECTIONS
1
2
+
-
+
-
SMART ENERGY MONITOR
O
O
O
O
A
Multi-Page LCD screen that oers the following information:
– Real-time energy usage.
– Firmware and Mac Address of the module.
– UID of the connected Host
– Real-time Bluetooth status connectivity icon.
– Module set-up and calibration screens.
B
PAIR Button - The PAIR button is a multi-use button. The
duration that the button is pressed and held determines the
function that gets initiated:
– Press and Release - Cycles through the screens available
on the LCD (POWER > POWER > INFO 1 > INFO 2).
– Press and hold - Press and hold for 2 second to put the
module into pairing mode. Press and hold for greater than
5 seconds to reset the module.
C
CT Connections - Connect a current transformer to each CT
Connection input port labeled 1 and 2, observing polarity
when making connections. Refer to the Install the Current
Transformer section later in the document for additional
wiring information.
D
Pigtail Neutral - Connect the pigtail type neutral wire to the
neutral bar in the breaker panel.
E
120V AC Connection - Plug the module onto the 120V AC
bus bar in the breaker panel. The voltage on this connection
powers the module.
Minimum Supported Release
Savant OS da Vinci 10.x
Electrical and Safety Characteristics
Pollution Degree 2
Purpose of Control Energy Monitoring
Software Class A
Impulse Voltage 2500V
Standards
Wireless
Bluetooth 5 Low Energy (BLE)
– 2.4 GHz radio frequency
This meter will be tested and certified to the following standards:
ANSI C12.20-2015
American National Standard for Electricity
Meters - 0.5 Accuracy Class
ANSI C12.1-2014
American National Standard for Electric Meters
- Code of electricity Metering
Regulatory
Safety and Emissions
FCC Part 15 UL ICES 003
Contains FCC ID: PUU-HQC2SEM
Contains IC: 10798A-HQC2SEM
RoHS Compliant
Recommended Load Center Types
Refer to the Features section to the right for compatibility.
Power
Input Power
(powers the module)
120V AC (+/- 10%) @ 60 Hz, 0.1A (max)
Signal Input 0.333V AC @ 60Hz
Type of Action Type 1 action
Dimensions and Weights
Length Width Height Weight
Module
4.49 in.
(11.41 cm)
1.98 in.
(5.03 cm)
2.78 in.
(7.06 cm)
.54 lbs
(.24 kg)
Shipping
7.48 in.
(19.0 cm)
4.17 in.
(10.6 cm)
1.69 in.
(4.29 cm)
1.0 lbs.
(.45 kg)
Environmental
Temperature 32° to 104° F (0° to 40° C)
Humidity 5% to 85% Relative Humidity (non-condensing)
Location Indoor Use Only
Current Transformers
– ACTL-1250-250 Opt CO.2 250 Amp
– ACTL-1250-400 Opt CO.2 400 Amp
– ACTL-1250-600 Opt CO.2 600 Amp
Features
– The GPM-H2SEM-00 Smart Energy Monitor modules is compatible
with Schneider Homeline, Eaton BR, Siemens, and Powermark Gold
load centers with a one-inch on-center bus bar.
– Energy monitoring; +/- 0.5% revenue grade accuracy / 1 sec sample
time.
– The module communicates with a Panel Bridge Controller or Savant
Power Director using Bluetooth Low Energy (BLE) technology.
– Color LCD display for easy identification.
Smart Energy Monitor Module (Supports 1-inch On-Center Load Centers)
Quick Reference and Installation Guide
Specifications
Box Contents
Accessories
Descriptions
(1) Smart Energy Monitor Module (SEM)
– GPM-H2SEM-xx w/Pigtail type neutral
(1) 4-pin screw down plug-in connector (028-9395)
(1) Product Information and Regulatory Insert (009-1950)
(1) Quick Reference and Installation Guide (this document)
Construction of Control
Open Type Independently mounted for flush mounting