83
LCD has extra horizontal or vertical lines
displayed.
LCD inverter I
LCD inverter
LCD cabl
LCD
Main Board
Indicator-Related Symptoms
Symptom / Error Action in Sequence
Indicator incorrectly remains off or on, but
system runs correctly
Reconnect the inverter board
Inverter board
Main Board
Power-Related Symptoms
Symptom / Error Action in Sequence
Power shuts down during operation Power source (battery pack and power adapter). See Power
System Check on page 77.
Battery pack
Power adapter
Hard drive & battery connection board
Main Board
The system doesnt power-on. Power source (battery pack and power adapter). See Power
System Check on page 77.
Battery pack
Power adapter
Hard drive & battery connection board
Main Board
The system doesnt power-off. Power source (battery pack and power adapter). See Power
System Check on page 77.
Hold and press the power switch for more than 4 seconds.
Main Board
Battery cant be charged See Check the Battery Pack on page 77.
Battery pack
Main Board
PCMCIA/Smart Card-Related Symptoms
Symptom / Error Action in Sequence
System cannot detect the PC Card (PCMCIA) PCMCIA/Smart Card slot assembly
Main Board
System cannot detect the Smart Card Smart Card
PCMCIA/Smart Card slot assembly
Main Board
PCMCIA/Smart Card slot pin is damaged. PCMCIA/Smart Card slot assembly
Memory-Related Symptoms
Symptom / Error Action in Sequence
Memory count (size) appears different from
actual size.
Enter BIOS Setup Utility to execute Load Default Settings, then
reboot system.
DIMM
Main Board
LCD-Related Symptoms
Symptom / Error Action in Sequence