Operation Manual
23
5.3.3.6 Motion Detection
Click “Motion Detect” icon under “Sys Setup”, switch to interface as
Picture 5-16 shows. When the system detects a mobile signal reaches a
preset sensitivity occurs, motion detection alarm and the linkage function
will be initiated by analyzing the video image.
Picture 5-16
Channel No: Select the motion detection channel. 2 option: Single and
All), for the Single channel, you need to choose the particular channel.
Switch Link: Reverse video means selected; turn on the motion
detection function.
Sensitivity: 6 values can be set for the sensitivity.
Buzzer on: Reverse video means selected. The system will trigger the
buzzer alarm when motion detect.
Buzzer time: Set the buzzer alarm duration.
Record channel: Reverse video means selected. Select the wanted
video channel, and the system will trigger the video signal of the
selected channel.
Record time: Set the trigger recording duration.
Default: Recover all the alarm setting parameters to the default values.
Save: Save the set parameters of current menu.
Cancel: Don’t save the set parameters of current menu.
5.3.3.7 PTZ Setup
In the preview screen,select a channel preview window, click the right
mouse button and click PTZ control options, the preview screen will switch to
the single-channel display, and PTZ control interface appears in the lower