Installation Manual

Wiring
Wiring Figure
3. Connect the u-lugs to the terminals Match the wire colors/labels with the labels on
the terminal block, and rmly screw the u-lug of each wire to its corresponding terminal.
4. Clamp down the cable with designated cable clamp.
5. Insulate unused wires with electrical tape. Keep them away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.
Harmonic declaration
"The equipment M4OB-36HFN8-Q complies with IEC 61000-3-12 provided that the shortcircuit power
Ssc is greater than or equal to 4787737.5 at the interface point between the user’s supply and the
public system. It is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment is con-nected
only to a supply with a short-circuit power Ssc greater than or equal to 4787737.5."
"The equipment M5OD-42HFN8-Q complies with IEC 61000-3-12 provided that the shortcircuit power
Ssc is greater than or equal to 3190042.5 at the interface point between the user’s supply and the
public system. It is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment is con-nected
only to a supply with a short-circuit power Ssc greater than or equal to 3190042.5."
NOTE: Refer to the following gures if end-users wish to perform their own wiring.
Run the main power cord through the lower line-outlet of the cord clamp.
---- This symbol indicates eld wiring.
CAUTION
Connect the connective cables to the terminals, as identied, with their matching numbers
on the terminal block of the indoor and outdoor units. For example, in the US models shown
in the following diagram, Terminal L1(A) of the outdoor unit must connect with terminal L1
on the indoor unit.