Owner`s manual
Technical Data
Trouble-Shooting Guide
System does not
work when reverse
gear is engaged
Audio alarm/same
distance displayed
continuously
No audio alarm
when obstacle is in
detection range
False alarm
Sensor detects the ground
Bad sensor connection
Sensor detects the ground
System sensitivity is
too high
Adjust angle of sensor
installation
Bad jack connection
Bad connection of main
power lead
Check power lead
Reconnect all jacks
Reset the system
Reset the system
Reconnect sensors
Adjust angle of sensor
installation
Ask your dealer/pro -
fessional installer to
adjust sensitivity
DC18~30V
Below 48MA
-30 C~80 C
-35 C~85 C
40KHz ± 1KHz
Specified voltage
Operation voltage
range
Operation current
Operation
Temperature
Storage
Temperature
Operation
frequency
DC24V
ITEM SPECIFICATION
-30 C~80 C
-40 C~85 C
40KHz ± 1KHz
45 Horizontal
45 Vertical
Ultrasonic wave
Operation voltage
range
Operation
temperature
Storage
temperature
Operation
frequency
Detection angle
Detection method
DC 7.5~8.5V
ITEM SPECIFICATION
9
P5000 Series Owners Manual 12/16/04 5:16 PM Page 9
PROBLEM REASON SOLUTION
SENSORCONTROL BOX